An indexed offset distance of the tricuspid septal leaflet ⩾8 mm/m2 is a quantitative criterion for the diagnosis of Ebstein's anomaly. The purpose of this study was to investigate the validity of this criterion for the discrimination of Ebstein's anomaly from pulmonary atresia with intact ventricular septum in neonatal patients. A total of 122 neonatal patients, 56 with Ebstein's anomaly and 66 with pulmonary atresia with intact ventricular septum, were enrolled. Diagnosis of each anomaly was based on typical morphologic features. Echocardiographic variables, including the offset distance of the tricuspid septal leaflet, were measured via an offline analysis of images recorded before 1 month of age. The offset distance of the tricuspid septal leaflet was indexed by the body surface area, and the indexed offset distances in the Ebstein's anomaly and pulmonary atresia with intact ventricular septum groups were 34.2 mm/m2 (7.1-119.1 mm/m2) and 7.2 mm/m2 (0.0-25.6 mm/m2), respectively. The indexed offset distance was ⩾8 mm/m2 in 29 (43.9%) of the patients with pulmonary atresia with intact ventricular septum; clinical and echocardiographic characteristics were comparable between these 29 patients and the remaining 37 patients with pulmonary atresia with intact ventricular septum. When an indexed offset distance ⩾8 mm/m2 was applied as a cut-off for the diagnosis of Ebstein's anomaly, the sensitivity was 0.963 and the specificity was 0.561. In conclusion, indexed offset distance ⩾8 mm/m2 cannot be used as a cut-off for the diagnosis of complicated Ebstein's anomaly in neonatal patients with pulmonary atresia with intact ventricular septum.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1017/S1047951114001206 | DOI Listing |
Sensors (Basel)
December 2024
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia.
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions.
View Article and Find Full Text PDFBone Jt Open
January 2025
Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Japan.
Aims: Excellent outcomes have been reported following CT-based robotic arm-assisted total hip arthroplasty (rTHA) compared with manual THA; however, its superiority over CT-based navigation THA (nTHA) remains unclear. This study aimed to determine whether a CT-based robotic arm-assisted system helps surgeons perform accurate cup placement, minimizes leg length, and offsets discrepancies more than a CT-based navigation system.
Methods: We studied 60 hips from 54 patients who underwent rTHA between April 2021 and August 2023, and 45 hips from 44 patients who underwent nTHA between January 2020 and March 2021 with the same target cup orientation at the Department of Orthopedic Surgery at Ozu Memorial Hospital, Japan.
Heliyon
December 2024
Department of Electrical Engineering, Pohang University of Science and Technology (POSTECH), 77 Cheongam-Ro, Nam-Gu, Pohang, Gyeongbuk, 37673, Republic of Korea.
This study investigates human semicircular canal (SCC) dynamics under off-center rotational conditions. Previous research has modeled human rotational perception and the dynamic response of the SCCs by assuming a centered rotation state, where the rotation axis aligns with the SCC's center. However, this assumption is not representative of most real-life rotational situations.
View Article and Find Full Text PDFJ Shoulder Elbow Surg
December 2024
Department of Mechanical & Aerospace Engineering, University of Florida, 330MAE-A P.O. Box 116250, Gainesville, FL, USA 32611.
Background: Postoperative assessment following reverse total shoulder arthroplasty (rTSA) typically involves plain radiographs to evaluate implant positioning parameters, such as humeral distalization and lateralization along with medialization and distalization of the center of rotation (COR). However, the precision of these radiographic measurements remains unclear. This study aimed to validate the accuracy of radiographic two-dimensional (2D) measurements compared to three-dimensional (3D) surface model-based measurements derived from CT data for evaluating postoperative parameters in rTSA.
View Article and Find Full Text PDFJ Int Med Res
December 2024
Hanshan Normal University, Chaozhou, Guangdong Province, China.
Objective: This study investigated a method for assessing movement patterns in patients with functionally limited temporomandibular disorders using minimal equipment. The aim was to enable clinicians to better understand temporomandibular joint function, support treatment decision-making, and provide data for documenting disease progression.
Methods: This retrospective, observational study included 45 patients with functionally limited temporomandibular disorders (Group A) and 40 healthy volunteers (Group B).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!