Shear wave speed can be used to assess tissue elasticity, which is associated with tissue health. Ultrasound shear wave elastography techniques based on measuring the propagation speed of the shear waves induced by acoustic radiation force are becoming promising alternatives to biopsy in liver fibrosis staging. However, shear waves generated by such methods are typically very weak. Therefore, the penetration may become problematic, especially for overweight or obese patients. In this study, we developed a new method called external vibration multi-directional ultrasound shearwave elastography (EVMUSE), in which external vibration from a loudspeaker was used to generate a multi-directional shear wave field. A directional filter was then applied to separate the complex shear wave field into several shear wave fields propagating in different directions. A 2-D shear wave speed map was reconstructed from each individual shear wave field, and a final 2-D shear wave speed map was constructed by compounding these individual wave speed maps. The method was validated using two homogeneous phantoms and one multi-purpose tissue-mimicking phantom. Ten patients undergoing liver magnetic resonance elastography (MRE) were also studied with EVMUSE to compare results between the two methods. Phantom results showed EVMUSE was able to quantify tissue elasticity accurately with good penetration. In vivo EVMUSE results were well correlated with MRE results, indicating the promise of using EVMUSE for liver fibrosis staging.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4216646 | PMC |
http://dx.doi.org/10.1109/TMI.2014.2332542 | DOI Listing |
Ultrasound Med Biol
January 2025
School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan ROC; Center of Physical Therapy, National Taiwan University Hospital, Taipei, Taiwan ROC. Electronic address:
Objective: This study aimed to validate the ultrasound speckle tracking (UST) algorithm, determine the optimal probe location by comparing normalized cross-correlation (NCC) values of muscle displacement at two locations (proximal vs. middle) of the biceps femoris long head (BFlh) using the UST, and investigate the effects of Nordic hamstring curl exercise (NHE) training on BFlh displacement.
Methods: UST efficacy was verified with ex vivo uniaxial testing of porcine leg muscles.
J Clin Med
January 2025
Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Italy.
: Carotid artery stenosis (CAS) is one of the main causes of stroke, and the vulnerability of plaque has been proved to be a determinant. A joint analysis of shear wave elastography, a radiofrequency echo-based wall tracking technique for arterial stiffness evaluation, and of autonomic and baroreflex function is proposed to noninvasively, preoperatively assess plaque vulnerability in asymptomatic CAS patients scheduled for carotid endarterectomy. : Elastographic markers of arterial stiffness were derived preoperatively in 78 CAS patients (age: 74.
View Article and Find Full Text PDFBiomedicines
January 2025
Centro Malattie Apparato Digerente-CEMAD, Fondazione Policlinico Universitario A. Gemelli, IRCCS, 00168 Roma, Italy.
The aim of this study was to investigate the accuracy in fibrosis staging of a novel shear wave elastography (SWE) device (S-Shearwave Imaging by Samsung) and a previously validated 2D-SWE by Supersonic Imagine (SSI) in patients with biopsy proven metabolic dysfunction-associated steatotic liver disease (MASLD). This prospective study included 75 consecutive patients with MASLD who underwent liver biopsy for suspected MASH. All patients underwent S-Shearwave Imaging by Samsung and 2D-SWE with SSI on the same day of liver biopsy.
View Article and Find Full Text PDFDiagnostics (Basel)
January 2025
Odense Respiratory Research Unit (ODIN), Department of Clinical Research, Faculty of Health Sciences, University of Southern Denmark, 5000 Odense, Denmark.
: Ultrasound is a valuable diagnostic tool in the diagnostic work-up of dyspnea and can identify even small pleural effusions. The incorporation of shear wave elastography (SWE) represents a possible tool in stratifying pleural effusions by the risk of underlying malignancy. No previous studies on ultrasound with the incorporation of SWE have been conducted in an emergency department (ED), where such stratification might have a clinical impact by hastening referrals for the diagnostic work-up of underlying malignancy.
View Article and Find Full Text PDFPediatr Nephrol
January 2025
Department of Nephrology, Key Laboratory of Major Diseases in Children, Ministry of Education, National Center for Children's Health, Beijing Children's Hospital, Capital Medical University, Beijing, China.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!