Automated Percentage of Breast Density Measurements for Full-field Digital Mammography Applications.

Acad Radiol

Department of Cancer Imaging and Metabolism, H. Lee Moffitt Cancer Center, 12901 Magnolia Drive, Tampa, FL 33612. Electronic address:

Published: August 2014

Rationale And Objectives: Increased mammographic breast density is a significant risk factor for breast cancer. A reproducible, accurate, and automated breast density measurement is required for full-field digital mammography (FFDM) to support clinical applications. We evaluated a novel automated percentage of breast density measure (PDa) and made comparisons with the standard operator-assisted measure (PD) using FFDM data.

Methods: We used a nested breast cancer case-control study matched on age, year of mammogram and diagnosis with images acquired from a specific direct x-ray conversion FFDM technology. PDa was applied to the raw and clinical display (or processed) representation images. We evaluated the transformation (pixel mapping) of the raw image, giving a third representation (raw-transformed), to improve the PDa performance using differential evolution optimization. We applied PD to the raw and clinical display images as a standard for measurement comparison. Conditional logistic regression was used to estimate the odd ratios (ORs) for breast cancer with 95% confidence intervals (CI) for all measurements; analyses were adjusted for body mass index. PDa operates by evaluating signal-dependent noise (SDN), captured as local signal variation. Therefore, we characterized the SDN relationship to understand the PDa performance as a function of data representation and investigated a variation analysis of the transformation.

Results: The associations of the quartiles of operator-assisted PD with breast cancer were similar for the raw (OR: 1.00 [ref.]; 1.59 [95% CI, 0.93-2.70]; 1.70 [95% CI, 0.95-3.04]; 2.04 [95% CI, 1.13-3.67]) and clinical display (OR: 1.00 [ref.]; 1.31 [95% CI, 0.79-2.18]; 1.14 [95% CI, 0.65-1.98]; 1.95 [95% CI, 1.09-3.47]) images. PDa could not be assessed on the raw images without preprocessing. However, PDa had similar associations with breast cancer when assessed on 1) raw-transformed (OR: 1.00 [ref.]; 1.27 [95% CI, 0.74-2.19]; 1.86 [95% CI, 1.05-3.28]; 3.00 [95% CI, 1.67-5.38]) and 2) clinical display (OR: 1.00 [ref.]; 1.79 [95% CI, 1.04-3.11]; 1.61 [95% CI, 0.90-2.88]; 2.94 [95% CI, 1.66-5.19]) images. The SDN analysis showed that a nonlinear relationship between the mammographic signal and its variation (ie, the biomarker for the breast density) is required for PDa. Although variability in the transform influenced the respective PDa distribution, it did not affect the measurement's association with breast cancer.

Conclusions: PDa assessed on either raw-transformed or clinical display images is a valid automated breast density measurement for a specific FFDM technology and compares well against PD. Further work is required for measurement generalization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4166439PMC
http://dx.doi.org/10.1016/j.acra.2014.04.006DOI Listing

Publication Analysis

Top Keywords

breast density
24
breast cancer
20
clinical display
20
100 [ref]
16
breast
12
[95%
12
pda
10
automated percentage
8
percentage breast
8
full-field digital
8

Similar Publications

Introduction Incorporation of mammographic density to breast cancer risk models could improve risk stratification to tailor screening and prevention strategies according to risk. Robust evaluation of the value of adding mammographic density to models with comprehensive information on questionnaire-based risk factors and polygenic risk score is needed to determine its effectiveness in improving risk stratification of such models. Methods We used the Individualized Coherent Absolute Risk Estimator (iCARE) tool for risk model building and validation to incorporate density to a previously validated literature-based model with questionnaire-based risk factors and a 313-variant polygenic risk score (PRS).

View Article and Find Full Text PDF

Purpose: This study aims to explore the effects of Tai Chi Chuan (TCC) on physical function, hematological metabolic biomarkers, sleep quality, and mental health in breast cancer patients.

Methods: This was a prospective clinical trial that involved 37 breast cancer patients who had completed surgery treatment. Participants' motor function, hematological examination, and self-rated questionnaire were assessed at the baseline and after the intervention.

View Article and Find Full Text PDF
Article Synopsis
  • Self-supervised learning (SSL) is increasingly being used in medical imaging, particularly through methods like the Jigsaw puzzle task, which helps models learn features and relationships within images without needing labeled data.
  • The study evaluated different pre-training methods on mammographic images from the Chinese Mammography Database, comparing the effectiveness of models that used Jigsaw puzzles, ImageNet tasks, or no pre-training at all in detecting breast cancer.
  • Results showed that models utilizing the Jigsaw puzzle task achieved the highest area under the curve (AUC) scores, indicating its potential to improve classification accuracy even with limited data.
View Article and Find Full Text PDF
Article Synopsis
  • Understanding the ecological dynamics and carbon storage potential of Atlantic tropical forests in Cameroon is essential for effective management and conservation efforts.
  • The study involved creating 12 permanent plots to analyze plant communities, collect environmental data, and assess carbon stocks by measuring trees with diameters ≥10 cm.
  • Utilizing Multivariate Regression Trees and multiple regression models, researchers identified distinct plant communities and their relations to environmental factors, revealing important insights into tree density, biomass variability, and the distribution of carbon stocks.
View Article and Find Full Text PDF

Objectives: Shear-wave elastography (SWE) provides valuable stiffness within breast masses, making it a useful supplement to conventional ultrasound imaging. Super-resolution ultrasound (SRUS) imaging enhances microvascular visualization, aiding in the differential diagnosis of breast masses. Current clinical ultrasound diagnosis of breast cancer primarily relies on gray-scale ultrasound.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!