Estimation of lung motion fields in 4D CT data by variational non-linear intensity-based registration: A comparison and evaluation study.

Phys Med Biol

Department of Computational Neuroscience, University Medical Center Hamburg-Eppendorf, Germany. Institute of Medical Informatics, University of Lübeck, Germany.

Published: August 2014

Accurate and robust estimation of motion fields in respiration-correlated CT (4D CT) images, usually performed by non-linear registration of the temporal CT frames, is a precondition for the analysis of patient-specific breathing dynamics and subsequent image-supported diagnostics and treatment planning. In this work, we present a comprehensive comparison and evaluation study of non-linear registration variants applied to the task of lung motion estimation in thoracic 4D CT data. In contrast to existing multi-institutional comparison studies (e.g. MIDRAS and EMPIRE10), we focus on the specific but common class of variational intensity-based non-parametric registration and analyze the impact of the different main building blocks of the underlying optimization problem: the distance measure to be minimized, the regularization approach and the transformation space considered during optimization. In total, 90 different combinations of building block instances are compared. Evaluated on proprietary and publicly accessible 4D CT images, landmark-based registration errors (TRE) between 1.14 and 1.20 mm for the most accurate registration variants demonstrate competitive performance of the applied general registration framework compared to other state-of-the-art approaches for lung CT registration. Although some specific trends can be observed, effects of interchanging individual instances of the building blocks on the TRE are in general rather small (no single outstanding registration variant existing); the same level of accuracy is, however, associated with significantly different degrees of motion field smoothness and computational demands. Consequently, the building block combination of choice will depend on application-specific requirements on motion field characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/59/15/4247DOI Listing

Publication Analysis

Top Keywords

registration
9
lung motion
8
motion fields
8
comparison evaluation
8
evaluation study
8
non-linear registration
8
registration variants
8
building blocks
8
building block
8
motion field
8

Similar Publications

Background: Acute kidney injury (AKI) is a common complication in hospitalized older patients, associated with increased morbidity, mortality, and health care costs. Major adverse kidney events within 30 days (MAKE30), a composite of death, new renal replacement therapy, or persistent renal dysfunction, has been recommended as a patient-centered endpoint for clinical trials involving AKI.

Objective: This study aimed to develop and validate a machine learning-based model to predict MAKE30 in hospitalized older patients with AKI.

View Article and Find Full Text PDF

Research Participants' Engagement and Retention in Digital Health Interventions Research: Protocol for Mixed Methods Systematic Review.

JMIR Res Protoc

January 2025

Department of Women's and Children's Health, Participatory eHealth and Health Data Research Group, Uppsala University, Uppsala, Sweden.

Background: Digital health interventions have become increasingly popular in recent years, expanding the possibilities for treatment for various patient groups. In clinical research, while the design of the intervention receives close attention, challenges with research participant engagement and retention persist. This may be partially due to the use of digital health platforms, which may lack adequacy for participants.

View Article and Find Full Text PDF

Objective: Malalignment following cervical spine deformity (CSD) surgery can negatively impact outcomes and increase complications. Despite the growing ability to plan alignment, it remains unclear whether preoperative goals are achieved with surgery. The objective of this study was to assess how good surgeons are at achieving their preoperative goal alignment following CSD surgery.

View Article and Find Full Text PDF

Background: Young gay, bisexual, and other men who have sex with men have been referred to as a "hard-to-reach" or "hidden" community in terms of recruiting for research studies. With widespread internet use among this group and young adults in general, web-based avenues represent an important approach for reaching and recruiting members of this community. However, little is known about how participants recruited from various web-based sources may differ from one another.

View Article and Find Full Text PDF

Background: The SEER Registry contains U.S. cancer statistics.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!