A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3124
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of copper corrosion from frameless copper IUDs after long-term in utero residence. | LitMetric

Objective: To assess the site-specific corrosive behavior of the frameless intrauterine device (IUD) following long-term exposure to the uterine environment.

Study Design: A qualitative and morphological study using X-ray diffraction (XRD) and scanning electron microscopy (SEM).

Results: Three GyneFix® IUDs that were in site up to 150 months were examined. In utero corroded copper sleeves were divided into 10 different groups based on their shape (U or O), orientation (inside or outside) and in utero residence time. XRD indicated the presence of solely cuprite (Cu2O) as corrosion product on both the inside and the outside of the copper sleeves, regardless of their shape. These results were confirmed by backscattered electron micrographs recorded on the inside, the outside and the cross-section of the IUD sleeve. SEM results suggest that shape and orientation slightly affect the corrosion rate.

Conclusion: The apparent copper loss from both sides of GyneFix copper tubes proves that both sides are a potential copper source and therefore justifies the design of GyneFix IUD. This could be beneficial for women as the IUD could be reduced in size and therefore better tolerated. The impact on bleeding could also be minimized.

Implication Statement: Release of copper ions from both sides of the copper tubes of the frameless GyneFix® IUD allows the IUD to be reduced in size, contributing to better toleration. The impact on menstrual bleeding is also minimized by a smaller size of the foreign body.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.contraception.2014.05.009DOI Listing

Publication Analysis

Top Keywords

copper
8
utero residence
8
copper sleeves
8
shape orientation
8
copper tubes
8
iud reduced
8
reduced size
8
iud
6
assessment copper
4
copper corrosion
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!