  • The study used swept source optical coherence tomography (SS-OCT) to measure choroidal thickness and volume in healthy eyes.
  • A total of 122 patients were examined, with specific scans focusing on the fovea and measurements of choroidal thickness conducted both manually and automatically.
  • Results indicated that choroidal thickness is greatest under the fovea and correlates significantly with age and axial length, providing a useful tool for tracking changes in choroidal abnormalities over time.

Article Abstract

Purpose: To report choroidal thickness and volume in healthy eyes using swept source optical coherence tomography (SS-OCT).

Methods: A prospective observational study of 122 patients examined with swept source OCT (DRI-OCT, Topcon, Japan). In each eye, we performed 256 horizontal scans, 12 mm in length and centered on the fovea. We calculated choroidal thickness manually with a built-in caliper and automatically using DRI-OCT mapping software. Choroidal volume was also automatically calculated. We measured axial length with optical low-coherence reflectometry (Lenstar LS 900, Haag-Streit, Switzerland).

Results: The choroid has focally increased thickness under the fovea. Choroid was thinnest in the outer nasal quadrant. In stepwise regression analysis, age was estimated as the most significant factor correlating with decreased choroidal thickness (F=23.146, P<0.001) followed by axial length (F=4.902, P=0.03). Refractive error was not statistically significant (F=1.16, P=0.28).

Conclusions: SS-OCT is the first commercially available system that can automatically create choroidal thickness and volume maps. Choroidal thickness is increased at the fovea and is thinnest nasally. Age and axial length are critical for the estimation of choroidal thickness and volume. Choroidal measurements derived from SS-OCT images have potential value for objectively documenting disease-related choroidal thickness abnormalities and monitoring progressive changes over time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4075071PMC
http://dx.doi.org/10.1155/2014/639160DOI Listing

Publication Analysis

Top Keywords

choroidal thickness
16
swept source
12
thickness volume
8
axial length
8
source optical
8
optical coherence
8
coherence tomography
8
optical low-coherence
8
low-coherence reflectometry
8
thickness
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!