Current and emerging MR imaging techniques for the diagnosis and management of CSF flow disorders: a review of phase-contrast and time-spatial labeling inversion pulse.

AJNR Am J Neuroradiol

Division of Neurosurgery (J.G.M.), Children's Hospital Los Angeles, Los Angeles, California Department of Neurological Surgery (J.G.M.), Keck School of Medicine, University of Southern California, Los Angeles, California.

Published: April 2015

This article provides an overview of phase-contrast and time-spatial labeling inversion pulse MR imaging techniques to assess CSF movement in the CNS under normal and pathophysiologic situations. Phase-contrast can quantitatively measure stroke volume in selected regions, notably the aqueduct of Sylvius, synchronized to the heartbeat. Judicious fine-tuning of the technique is needed to achieve maximal temporal resolution, and it has limited visualization of CSF motion in many CNS regions. Phase-contrast is frequently used to evaluate those patients with suspected normal pressure hydrocephalus and a Chiari I malformation. Correlation with successful treatment outcome has been problematic. Time-spatial labeling inversion pulse, with a high signal-to-noise ratio, assesses linear and turbulent motion of CSF anywhere in the CNS. Time-spatial labeling inversion pulse can qualitatively visualize whether CSF flows between 2 compartments and determine whether there is flow through the aqueduct of Sylvius or a new surgically created stoma. Cine images reveal CSF linear and turbulent flow patterns.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7964307PMC
http://dx.doi.org/10.3174/ajnr.A4030DOI Listing

Publication Analysis

Top Keywords

time-spatial labeling
16
labeling inversion
16
inversion pulse
16
imaging techniques
8
phase-contrast time-spatial
8
aqueduct sylvius
8
linear turbulent
8
csf
6
current emerging
4
emerging imaging
4

Similar Publications

Comparison of 3D BFFE and 3D TRANCE on pulmonary artery imaging with two T-SLIP placement strategies.

Magn Reson Imaging

January 2025

Department of Radiology, People's Hospital of Xinjiang Uygur Autonomous Region, Urumqi, Xinjiang Uygur Autonomous Region, China. Electronic address:

3D BFFE and TRANCE can provide a visualization of pulmonary vessels without injection of contrast agent. T-SLIP can observe a large area of vessels using an arterial spin labeling technique. 3D BFFE and TRANCE with two T-SLIP placement strategies were compared on pulmonary artery imaging.

View Article and Find Full Text PDF

A temporal-spectral graph convolutional neural network model for EEG emotion recognition within and across subjects.

Brain Inform

December 2024

Brain Cognition and Intelligent Computing Lab, Department of Artificial Intelligence, School of Informatics, Xiamen University, Xiamen, Fujian, China.

Article Synopsis
  • EEG-based emotion recognition analyzes neural activity to predict emotions but faces challenges due to the variability of data across subjects in time, frequency, and spatial domains.
  • To tackle these issues, a new model called Temporal-Spectral Graph Convolutional Network (TSGCN) is introduced, which uses a Minimum Category Confusion loss to align subjective and predefined emotional labels.
  • Experiments show that TSGCN outperforms existing methods in emotion recognition and exhibits high robustness, largely due to its unique approach and the integration of Deep and Shallow feature Dynamic Adversarial Learning for cross-subject adaptation.
View Article and Find Full Text PDF

Transepithelial electrical resistance (TEER) measurement is a label free, rapid and real-time technique, which is commonly used to evaluate the integrity of cell barriers. TEER characterization is important for applications, such as tissue (brain, intestines, lungs) barrier modeling, drug screening, and cell growth monitoring. Traditional TEER methods usually only show the average impedance of the whole cell layer, and lack accuracy and the characterization of internal spatial differences within cell layer regions.

View Article and Find Full Text PDF

Next Generation of Solid Target Radionuclide Antibody Conjugates for Tumor Immuno-Therapy.

J Labelled Comp Radiopharm

November 2024

Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), NMPA Key Laboratory for Research and Evaluation of Radiopharmaceuticals, Department of Nuclear Medicine, Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), NMPA Key Laboratory for Research and Evaluation of Radiopharmaceuticals, Peking University Cancer Hospital & Institute, Beijing, China.

Immune checkpoint therapy has emerged as an effective treatment option for various types of cancers. Key immune checkpoint molecules, such as cytotoxic T-lymphocyte-associated protein 4 (CTLA-4), programmed cell death protein 1 (PD-1), and lymphocyte activation gene 3 (LAG-3), have become pivotal targets in cancer immunotherapy. Antibodies designed to inhibit these molecules have demonstrated significant clinical efficacy.

View Article and Find Full Text PDF

Cerebrospinal fluid (CSF) circulation diseases, such as hydrocephalus and syringomyelia, are common in small-breed dogs. In human patients with CSF circulation diseases, time-spatial labeling inversion pulse (time-SLIP) sequence performed to evaluate CSF flow before and after treatment allows visualization of the restoration of CSF movement. However, studies evaluating CSF flow using the time-SLIP method in small-breed dogs are limited.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!