Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Purpose: Irradiation of the Pharyngeal Superior Constrictor Muscle (PSCM) seems to play a crucial role in radiation-related swallowing dysfunctions. Purpose of our study was to quantify operator-related variability in the contouring of PSCM on Computed Tomography (CT) scans and adherence with contours derived from MR images.
Materials And Methods: Three sets of treatment planning CT and their corresponding MR images were selected. Contouring of the PSCM was performed using both a literature-based method, derived from literature review, and an optimized method, derived from Magnetic Resonance (MR) images thus obtaining "literature-based" and "optimized" contours. Each operator contoured the PSCM on CT scans according to both methods for three times in three different days. Inter- and intra-operator variability and adherence to a contour obtained from MR images (named "MR-derived" contour) were analyzed.
Results: Thirty-four operators participated and 612 contours were obtained. Both intra- and inter-operator variability and adherence to the "MR-derived" contour were significantly different between the two methods (p⩽0.05). The "optimized" method showed a lower intra- and inter-operator variability and a higher adherence to the "MR-derived" contour.
Conclusions: The "optimized" method ameliorates both operator-related variability and adherence with MR images.