Assessment of the complementarity of temperature and flow-rate for response normalisation of aerosol-based detectors.

J Chromatogr A

Australian Centre for Research on Separation Science (ACROSS) and Pfizer Analytical Research Centre (PARC), School of Chemistry, Faculty of Science, Engineering and Technology, University of Tasmania, Private Bag 75, Hobart, Tas. 7001, Australia. Electronic address:

Published: August 2014

The solvent dependency of the detection response is a major limitation of corona-charged aerosol detection (C-CAD). The present study empirically investigates the utility of temperature and flow-rate gradients to overcome solvent gradient limitations of C-CAD. In preliminary flow-injection investigations, it is demonstrated that the response of C-CAD remains relatively unaltered with variations in flow-rate when used with water-rich eluents. Based on these findings two separation approaches were developed and their utility for C-CAD response normalisation was demonstrated using a mixture of eight analytes. In the first approach the use of a solvent gradient is replaced with a temperature gradient performed under isocratic mobile phase conditions. Detection response is further enhanced by mixing a secondary stream of pure acetonitrile with the column effluent, yielding a 3-fold increase in detection response. In the second approach, flow-rate programming is used to improve speed of isocratic-temperature gradient separation. The use of simultaneous variation in flow-rate and column temperature reduced the separation time by 30%, with relatively uniform analyte response. Lastly, an inverse-gradient solvent compensation approach was used to evaluate the response homogeneity and the applicability of the above approaches for quantitative analysis. Good peak area reproducibility (RSD%<15%) and linearity (R(2)>0.994, on a log-scale) over the sample mass range of 0.1-10 μg was achieved. The response deviation across the mixture of eight compounds at seven concentration levels was 6-13% compared to 21-39% when a conventional solvent gradient was applied and this response deviation was comparable to that obtained in the inverse gradient solvent compensation approach. Finally, applicability of these approaches for typical pharmaceutical impurity profiling was demonstrated at a concentration of 5 μg/mL (0.1% of the principal compound).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2014.06.055DOI Listing

Publication Analysis

Top Keywords

detection response
12
solvent gradient
12
response
10
temperature flow-rate
8
response normalisation
8
solvent compensation
8
compensation approach
8
applicability approaches
8
response deviation
8
solvent
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!