Retinopathy of prematurity (ROP) is one of the leading and preventable causes of blindness. The investigation of choice for diagnosing ROP is binocular indirect ophthalmoscope (BIO) done by ophthalmologists. Since the number of ophthalmologists available to do BIO examination is limited, especially in developing countries, there is a need for an alternate, cheap, reliable and feasible test. Telemedicine imaging with Digital Retinal Photography (DRP) is one such alternate diagnostic test which can be performed easily by non-ophthalmologists, with adequate training. Our objective was to conduct a systematic review to evaluate the accuracy of DRP performed by trained personnel (non-ophthalmologists) in diagnosing clinically significant ROP. Medline, EMBASE, CINAHL and Cochrane databases were searched independently by two authors. Eligible studies were assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2, an evidence-based tool for the assessment of quality in systematic reviews of diagnostic accuracy studies. Six were included in the review (three prospective; N=120, three retrospective; N=579). Studies had methodological limitations on QUADAS-2. Because of the heterogeneity of studies, data could not be pooled to derive single-effect size estimates for sensitivity and specificity. The included studies reported sensitivity of 45.5-100% with the majority being more than 90%; specificity 61.7-99.8% with the majority being more than 90%, positive predictive value 61.5-96.6% and negative predictive value of 76.9-100% for diagnosing clinically significant ROP. We conclude that diagnostic accuracy of DRP must be established in prospective studies with adequate sample size where DRP is compared against the simultaneously performed BIO examination.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bjophthalmol-2014-304984 | DOI Listing |
Psychiatry Clin Psychopharmacol
December 2024
The Second Affiliated Hospital of Kunming Medical University, Kunming, Yunnan, China.
Background: This study aimed to investigate miRNAs and upstream regulatory transcription factors involved in schizophrenia (SZ) pathogenesis.
Methods: Differential expression of miRNAs and genes in SZ patients was investigated utilizing the gene expression omnibus dataset, gene ontology annotations, and Kyoto encyclopedia of genes and genomes (KEGG) pathway enrichment analysis. Real-time quantitative polymerase chain reaction experiments were conducted to validate the predictive screening of regulatory genes in peripheral blood samples from 20 SZ patients and 20 healthy controls.
Viruses
December 2024
Department of Pathology, National Institute of Infectious Diseases, Shinjuku-ku, Tokyo 162-8640, Japan.
Progressive multifocal leukoencephalopathy (PML) is a demyelinating disease caused by the JC polyomavirus (JCPyV). Based on the clinical criteria, PML is diagnosed via polymerase chain reaction (PCR) detection of JCPyV DNA in cerebrospinal fluid (CSF) in combination with neurological and imaging findings. Although the utility of CSF JCPyV testing using ultrasensitive PCR assays has been suggested, its potential requires further evaluation.
View Article and Find Full Text PDFViruses
November 2024
Laboratório Avançado de Saúde Pública, Instituto Gonçalo Moniz, Fundação Oswaldo Cruz (Fiocruz-BA), Salvador 40296-710, Bahia, Brazil.
Human T-cell leukemia virus type 1 (HTLV-1) is associated with an increased risk of tuberculosis (TB). This study aimed to evaluate the performance of the QuantiFERON-TB Gold (QFT) test for the diagnosis of (MTB) infection in HTLV-1-infected individuals. HTLV-1-infected participants were divided into four groups: HTLV-1-infected individuals with a history of tuberculosis (HTLV/TB), individuals with positive HTLV and tuberculin skin tests (HTLV/TST+) or negative TST (HTLV/TST-), and HTLV-1-negative individuals with positive TST results (HN/TST+).
View Article and Find Full Text PDFViruses
November 2024
Institute of Biology, ELTE Eötvös Loránd University, 1117 Budapest, Hungary.
The increasingly widespread application of next-generation sequencing (NGS) in clinical diagnostics and epidemiological research has generated a demand for robust, fast, automated, and user-friendly bioinformatics workflows. To guide the choice of tools for the assembly of full-length viral genomes from NGS datasets, we assessed the performance and applicability of four open-source bioinformatics pipelines (shiver-for which we created a user-friendly Dockerized version, referred to as dshiver; SmaltAlign; viral-ngs; and V-pipe) using both simulated and real-world HIV-1 paired-end short-read datasets and default settings. All four pipelines produced consensus genome assemblies with high quality metrics (genome fraction recovery, mismatch and indel rates, variant calling F1 scores) when the reference sequence used for assembly had high similarity to the analyzed sample.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia.
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!