A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reorientation simplified: a device for recording and reproducing the path of insertion for removable partial dentures. | LitMetric

Aim: The record of path of insertion on the dental cast is part of the dentist's work authorization to the dental laboratory technician. The path of insertion record enables the dental technician to replace the cast on a surveyor in the same position that the dentist selected. Analysis of factors that influence the path of insertion should determine a path of insertion that will reduce the potential for dislodgement and promote stability of removable partial denture (RPD).

Materials And Methods: The recording of the relation of a cast to a dental surveyor and the transfer of this relationship to the dental laboratory may be done by tripodization, by scoring the base of the cast, or by cementing a reference pin on the cast.

Conclusion: Recording the established path of insertion can be difficult when the procedure uses a cemented pin and the casts are mounted in an articulator. This article describes a procedure for innovative dowel pin and sleeve device to record the path of insertion of RPDs, which serves the same purpose as the cemented pin but can be easily removed and replaced.

Download full-text PDF

Source
http://dx.doi.org/10.4103/0970-9290.135939DOI Listing

Publication Analysis

Top Keywords

path insertion
28
removable partial
8
record path
8
dental laboratory
8
cemented pin
8
path
7
insertion
7
dental
5
reorientation simplified
4
simplified device
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!