Multiresolution edge detection using enhanced fuzzy c-means clustering for ultrasound image speckle reduction.

Med Phys

Department of Medical Physics, School of Medicine, University of Patras, Rion, GR 26504, Greece and Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030.

Published: July 2014

AI Article Synopsis

  • The study focuses on improving ultrasound image quality by employing a new algorithm that reduces speckle noise, enhancing the clarity of anatomical structures.
  • The algorithm uses enhanced fuzzy c-means clustering and multiresolution wavelet analysis to effectively distinguish between image edges and speckle noise, resulting in clearer, denoised images.
  • Test results from 34 ultrasound exams show that the new method outperforms existing techniques in speckle suppression and edge preservation, leading to improved diagnostic accuracy across various body areas.

Article Abstract

Purpose: Speckle suppression in ultrasound (US) images of various anatomic structures via a novel speckle noise reduction algorithm.

Methods: The proposed algorithm employs an enhanced fuzzy c-means (EFCM) clustering and multiresolution wavelet analysis to distinguish edges from speckle noise in US images. The edge detection procedure involves a coarse-to-fine strategy with spatial and interscale constraints so as to classify wavelet local maxima distribution at different frequency bands. As an outcome, an edge map across scales is derived whereas the wavelet coefficients that correspond to speckle are suppressed in the inverse wavelet transform acquiring the denoised US image.

Results: A total of 34 thyroid, liver, and breast US examinations were performed on a Logiq 9 US system. Each of these images was subjected to the proposed EFCM algorithm and, for comparison, to commercial speckle reduction imaging (SRI) software and another well-known denoising approach, Pizurica's method. The quantification of the speckle suppression performance in the selected set of US images was carried out via Speckle Suppression Index (SSI) with results of 0.61, 0.71, and 0.73 for EFCM, SRI, and Pizurica's methods, respectively. Peak signal-to-noise ratios of 35.12, 33.95, and 29.78 and edge preservation indices of 0.94, 0.93, and 0.86 were found for the EFCM, SIR, and Pizurica's method, respectively, demonstrating that the proposed method achieves superior speckle reduction performance and edge preservation properties. Based on two independent radiologists' qualitative evaluation the proposed method significantly improved image characteristics over standard baseline B mode images, and those processed with the Pizurica's method. Furthermore, it yielded results similar to those for SRI for breast and thyroid images significantly better results than SRI for liver imaging, thus improving diagnostic accuracy in both superficial and in-depth structures.

Conclusions: A new wavelet-based EFCM clustering model was introduced toward noise reduction and detail preservation. The proposed method improves the overall US image quality, which in turn could affect the decision-making on whether additional imaging and/or intervention is needed.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.4883815DOI Listing

Publication Analysis

Top Keywords

speckle reduction
12
speckle suppression
12
pizurica's method
12
proposed method
12
speckle
9
edge detection
8
enhanced fuzzy
8
fuzzy c-means
8
speckle noise
8
noise reduction
8

Similar Publications

Background: Changes in cardiac function and structure as well as their association with the cardiac autonomic nervous system remain incompletely characterized in children with stage 5 chronic kidney disease (CKD) receiving hemodialysis (HD).

Methods: A prospective observational cohort study was conducted on 40 Egyptian children with CKD on regular HD compared to 40 age- and sex-matched healthy children. All participants underwent thorough clinical examination, laboratory investigations, 24-h Holter monitoring, and 2D/4D echocardiographic study (conventional and advanced modalities).

View Article and Find Full Text PDF

Validation of Muscle Ultrasound Speckle Tracking and the Effect of Nordic Hamstring Exercise on Biceps Femoris Displacement.

Ultrasound Med Biol

January 2025

School and Graduate Institute of Physical Therapy, College of Medicine, National Taiwan University, Taipei, Taiwan ROC; Center of Physical Therapy, National Taiwan University Hospital, Taipei, Taiwan ROC. Electronic address:

Objective: This study aimed to validate the ultrasound speckle tracking (UST) algorithm, determine the optimal probe location by comparing normalized cross-correlation (NCC) values of muscle displacement at two locations (proximal vs. middle) of the biceps femoris long head (BFlh) using the UST, and investigate the effects of Nordic hamstring curl exercise (NHE) training on BFlh displacement.

Methods: UST efficacy was verified with ex vivo uniaxial testing of porcine leg muscles.

View Article and Find Full Text PDF

Background: Subcortical ischemic vascular dementia (SIVD) is a common subtype of vascular dementia. Currently, the bilateral common carotid artery stenosis (BCAS) mouse model is the most suitable SIVD rodent model. In this study, we investigated the functional and structural impairments in the hippocampus 1 month after BCAS.

View Article and Find Full Text PDF

The angular dependence of random laser (RL) generation in a commercially available rhodamine 6G (Rh6G) dye has been demonstrated using ZnO-CuO heterostructure as passive scatterers. The grass-like superstructure formed at a 1M:1M molar ratio of ZnO-CuO significantly enhances scattering, resulting in RL spikes with a full width at half maximum (FWHM) of just a few nanometer and a noticeable reduction in the RL threshold. RL emission spectra were collected over an angular spread of 0-180 degrees, revealing a remarkable shift in RL emission from 566 nm to 580 nm.

View Article and Find Full Text PDF

Objectives: Supra-normal left ventricular ejection fraction (snLVEF) represents a heterogeneous group with distinct prognoses. Left atrial (LA) strain, measured by speckle tracking echocardiography (STE), is a validated prognostic indicator. This study aimed to evaluate LA and left ventricular (LV) mechanical strains in hypertensive patients with snLVEF.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!