Hemodynamic quantification in brain arteriovenous malformations with time-resolved spin-labeled magnetic resonance angiography.

Stroke

From the CHU Rennes, Department of Neuroradiology, Rennes, France (H.R., J.-C.F., J.-Y.G.); Unité VISAGES U746 INSERM-INRIA, IRISA UMR CNRS 6074, University of Rennes, Rennes, France (H.R., E.B., P.M., C.N., J.-C.F., C.B., J.-Y.G); and MR Application & Workflow Development, Siemens AG, Healthcare Sector, Erlangen, Germany (P.S.).

Published: August 2014

Background And Purpose: Unenhanced time-resolved spin-labeled magnetic resonance angiography enables hemodynamic quantification in arteriovenous malformations (AVMs). Our purpose was to identify quantitative parameters that discriminate among different AVM components and to relate hemodynamic patterns with rupture risk.

Methods: Sixteen patients presenting with AVMs (7 women, 9 men; mean age 37.1±15.9 years) were assigned to the high rupture risk or low rupture risk group according to anatomic AVM characteristics and rupture history. High temporal resolution (<70 ms) unenhanced time-resolved spin-labeled magnetic resonance angiography was performed on a 3-T MR system. After dedicated image processing, hemodynamic quantitative parameters were computed. T tests were used to compare quantitative parameters among AVM components, between the high rupture risk and low rupture risk groups, and between the hemorrhagic and nonhemorrhagic groups.

Results: Among the quantitative parameters, time-to-peak (P<0.001) and maximum outflow gradient (P=0.01) allowed discriminating various intranidal flow patterns with significantly different values between feeding arteries and draining veins. With 9 AVMs classified into the high rupture risk group (whose 6 were hemorrhagic) and 7 into the low rupture risk group, the observed venous-to-arterial time-to-peak ratio was significantly lower in the high rupture risk (P=0.003) and hemorrhagic (P=0.001) groups.

Conclusions: Unenhanced time-resolved spin-labeled magnetic resonance angiography allows AVM-specific combined anatomic and quantitative analysis of AVM hemodynamics.

Download full-text PDF

Source
http://dx.doi.org/10.1161/STROKEAHA.114.006080DOI Listing

Publication Analysis

Top Keywords

hemodynamic quantification
8
arteriovenous malformations
8
time-resolved spin-labeled
8
spin-labeled magnetic
8
magnetic resonance
8
resonance angiography
8
rupture risk
8
quantification brain
4
brain arteriovenous
4
malformations time-resolved
4

Similar Publications

Background: Patients with low-flow, low-gradient (LFLG) aortic stenosis (AS) have precarious hemodynamics and are a fragile population for intervention. Quantification of aortic valve calcification (AVC) severity is a critical component of the evaluation for transcatheter aortic valve replacement (TAVR); this study aims to further clarify its utility for risk stratification in LFLG AS.

Methods: This retrospective study evaluated 467 patients with LFLG AS undergoing TAVR at a large quaternary-care hospital from January 2019 to December 2021.

View Article and Find Full Text PDF

Background: Traditional 2-dimensional (2D) ultrasound is a noninvasive method in the assessment of glomerular disease. Ultrasound elastography shows promise in evaluating renal fibrosis, which plays a key role in glomerular disease progression. However, research in pediatric cohorts is limited.

View Article and Find Full Text PDF

Objectives: To investigate the clinical value of fetal heart quantification (fetal HQ) in the evaluation of normal fetal heart size, morphology, and cardiac function at different gestational weeks.

Materials And Methods: A total of 101 pregnant women diagnosed with a healthy fetus by fetal echocardiography from September 2021 to December 2023 were selected and classified into four different periods of gestational weeks: 20-28 weeks (25 cases), 29-32 weeks (26 cases), 33-36 weeks (26 cases), and 37-40 weeks (24 cases). Quantitative analyses were performed by automatically tracking the endocardium using fetal HQ software that comes with the Voluson E10 from GE.

View Article and Find Full Text PDF

The main objectives of this work are to validate a 1D-0D unsteady solver with a distributed stenosis model for the patient-specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave-free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady-state and transient results and invasive measurements.

View Article and Find Full Text PDF

Angiogenesis Dynamics: A Computational Model of Intravascular Flow Within a Structural Adaptive Vascular Network.

Biomedicines

December 2024

LAETA-Laboratório Associado de Energia, Transportes e Aeronáutica, Universidade do Porto, 4200-165 Porto, Portugal.

Background: Understanding vascular development and the key factors involved in regulating angiogenesis-the growth of new blood vessels from pre-existing vasculature-is crucial for developing therapeutic approaches to promote wound healing. Computational techniques offer valuable insights into improving angiogenic strategies, leading to enhanced tissue regeneration and improved outcomes for chronic wound healing. While chorioallantoic membrane (CAM) models are widely used for examining fundamental mechanisms in vascular development, they lack quantification of essential parameters such as blood flow rate, intravascular pressure, and changes in vessel diameter.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!