Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The purpose of this study was to develop a silica nanoparticle-based immunosensor with laser-induced fluorescence (LIF) as a detection system. The proposed device was applied to quantify the immunoreactive trypsin (IRT) in cystic fibrosis (CF) newborn screening. A new ultrasonic procedure was used to extract the IRT from blood spot samples collected on filter papers. After extraction, the IRT reacted immunologically with anti-IRT monoclonal antibodies immobilized on a microfluidic glass chip modified with 3-aminopropyl functionalized silica nanoparticles (APSN-APTES-modified glass chips). The bounded IRT was quantified by horseradish peroxidase (HRP)-conjugated anti-IRT antibody (anti-IRT-Ab) using 10-acetyl-3,7-dihydroxyphenoxazine (ADHP) as enzymatic mediator. The HRP catalyzed the oxidation of nonfluorescent ADHP to highly fluorescent resorufin, which was measured by LIF detector, using excitation lambda at 561nm and emission at 585nm. The detection limits (LODs) calculated for LIF detection and for a commercial enzyme-linked immunosorbent assay (ELISA) test kit were 0.87 and 4.2ngml(-1), respectively. The within- and between-assay variation coefficients for the LIF detection procedure were below 6.5%. The blood spot samples collected on filter papers were analyzed with the proposed method, and the results were compared with those of the reference ELISA method, demonstrating a potential usefulness for the clinical assessment of IRT during the early neonatal period.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ab.2014.06.016 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!