Thoracolumbar and lumbar trauma account for the majority of traumatic spinal injuries. The mainstay of current treatments is still nonoperative therapy with bracing. Classic treatment algorithms reserved absolute surgical intervention for spinal trauma patients with neurological compromise or instability. Relative indications included incapacitating pain and obesity/body habitus making brace therapy ineffective. In the past decade, minimally invasive surgical (MIS) techniques for spine surgery have been increasingly used for degenerative conditions. These same minimally invasive techniques have seen increased use in trauma patients. The goal of minimally invasive surgery is to decrease surgical morbidity through decreased soft-tissue dissection while providing the same structural stability afforded by classic open techniques. These minimally invasive techniques involve percutaneous posterior pedicle fixation, vertebral body augmentation, and utilization of endoscopic and thoracoscopic techniques. While MIS techniques are somewhat in their infancy, an increasing number of studies are reporting good clinical and radiographic outcomes with these MIS techniques. However, the literature is still lacking high-quality evidence comparing these newer techniques to classic open treatments. This article reviews the relevant literature regarding minimally invasive spine surgery in the treatment of thoracolumbar and lumbar trauma.

Download full-text PDF

Source
http://dx.doi.org/10.3171/2014.5.FOCUS1494DOI Listing

Publication Analysis

Top Keywords

minimally invasive
24
spine surgery
12
thoracolumbar lumbar
12
mis techniques
12
invasive spine
8
surgery treatment
8
treatment thoracolumbar
8
lumbar trauma
8
trauma patients
8
techniques
8

Similar Publications

Background: Liver malignancies present substantial challenges to surgeons due to the extensive hepatic resections required, frequently resulting in posthepatectomy liver failure. Associating liver partition and portal vein ligation for staged hepatectomy (ALPPS) was designed to increase the resectable liver volume, yet it is associated with significant mortality and morbidity rates. Recently, minimally invasive techniques have been incorporated into ALPPS, with the potential to improve the procedure's safety profile whilst maintaining efficacy.

View Article and Find Full Text PDF

The widespread adoption of high-resolution computed tomography (CT) screening has led to increased detection of small pulmonary nodules, necessitating accurate localization techniques for surgical resection. This review examines the evolution, efficacy, and safety of various localization methods for small pulmonary nodules. Studies focusing on localization techniques for pulmonary nodules ≤30 mm in diameter were included, with emphasis on technical success rates and complication profiles.

View Article and Find Full Text PDF

Background: A surgical robot with force feedback can guarantee precise and gentle manipulation for endometrial repair, ensuring the effectiveness and safety of the manipulation. However, the design of force sensors for surgical robots is challenging due to the limited anatomical space and the requirement for continuous rotation.

Methods: This paper presents a novel force-sensing surgical instrument for endometrial repair, including an inner scraping instrument and an outer force sensing sheath.

View Article and Find Full Text PDF

Nanoencapsulated Optical Fiber-Based PEC Microelectrode: Highly Sensitive and Specific Detection of NT-proBNP and Its Implantable Performance.

Anal Chem

January 2025

Hunan Provincial Key Laboratory of Micro & Nano Materials Interface Science, College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.

Microelectrodes offer exceptional sensitivity, rapid response, and versatility, making them ideal for real-time detection and monitoring applications. Photoelectrochemical (PEC) sensors have shown great value in many fields due to their high sensitivity, fast response, and ease of operation. Nevertheless, conventional PEC sensing relies on cumbersome external light sources and bulky electrodes, hindering its miniaturization and implantation, thereby limiting its application in real-time disease monitoring.

View Article and Find Full Text PDF

Noninvasive evaluations of hormones can contribute to the assessment of health and welfare of animals. Variations in insulin levels and sensitivity, for example, have been linked to health concerns in non-human and human primates including insulin resistance, diabetes, and heart disease, the leading cause of death in zoo-housed gorillas. Few published studies have assessed insulin concentrations in western lowland gorillas (Gorilla gorilla gorilla), and all did so using serum.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!