A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High resolution, all-fiber, micro-machined sensor for simultaneous measurement of refractive index and temperature. | LitMetric

This paper presents a highly-sensitive, miniature, all-silica, dual parameter fiber-optic Fabry-Perot sensor, which is suitable for independent measurement of the refractive index and the temperature of the fluid surrounding the sensor. The experimental sensor was produced by a micromachining process based on the selective etching of doped silica glass and a simple assembly procedure that included fiber cleaving, splicing and etching of optical fibers. The presented sensor also allows for direct compensation of the temperature's effect on the fluid's refractive index change and consequently provides opportunities for the detection of very small changes in the surrounding fluid's composition. A measurement resolution of 2x10(-7) RIU was demonstrated experimentally for a component of the refractive index that is related purely to the fluid's composition. This resolution was achieved under non-stabilized temperature conditions. The temperature resolution of the sensor proved to be about 10(-3) °C. These high resolution measurements were obtained by phase-tracking of characteristic components in a Fourier transform of sensor's optical spectrum.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.22.016241DOI Listing

Publication Analysis

Top Keywords

high resolution
8
measurement refractive
8
refractive temperature
8
fluid's composition
8
sensor
6
resolution all-fiber
4
all-fiber micro-machined
4
micro-machined sensor
4
sensor simultaneous
4
simultaneous measurement
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!