Time-averaged intreatment prostate localization errors were calculated, for the first time, by three-dimensional prostate image cross-correlation between planning CT and intrafraction kilovoltage cone-beam CT (CBCT) during volumetric modulated arc therapy (VMAT). The intrafraction CBCT volume was reconstructed by an inhouse software after acquiring cine-mode projection images during VMAT delivery. Subsequently, the margin between a clinical target volume and a planning target volume (PTV) was obtained by applying the van Herk and variant formulas using the calculated localization errors. The resulting PTV margins were approximately 2 mm in lateral direction and 4 mm in craniocaudal and anteroposterior directions, which are consistent with the margin prescription employed in our facility.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4055024PMC
http://dx.doi.org/10.1155/2014/960928DOI Listing

Publication Analysis

Top Keywords

target volume
12
localization errors
12
planning target
8
planning intrafraction
8
volumetric modulated
8
modulated arc
8
arc therapy
8
validation planning
4
volume
4
volume margins
4

Similar Publications

Bibliometric analysis of glycolysis and prostate cancer research from 2004 to 2024.

Discov Oncol

January 2025

School of Rehabilitation Medicine and Health Care, Hunan University of Medicine, No. 492 Jinxi South Road, Huaihua, 418000, China.

Background: Prostate cancer (PCa) ranks as the second most common disease among men and the fourth most prevalent cancer worldwide. Enhanced glycolysis and excessive lactate secretion are recognized as critical factors driving the progression of various cancers. This study systematically investigated the research trends associated with glycolysis in PCa through bibliometric analysis.

View Article and Find Full Text PDF

Introduction: Digital trials are a promising strategy to increase the evidence base for common interventions and may convey considerable efficiency benefits in trial conduct. Although paediatric intensive care units (PICUs) are rich in routine electronic data, highly pragmatic digital trials in this field remain scarce. There are unmet evidence needs for optimal mechanical ventilation modes in paediatric intensive care.

View Article and Find Full Text PDF

The efficacy of aerial application and chemigation of insecticides is not well explored for western bean cutworm, Striacosta albicosta (Smith), management in corn. In the short term, inadequate application of insecticides can lead to control failures when insect pests are not effectively targeted. In the longer term, exposure to sublethal insecticide concentrations can contribute to the evolution of insecticide resistance.

View Article and Find Full Text PDF

Introduction: Prostate motion during external beam radiotherapy (EBRT) is common and typically managed using fiducial markers and cone beam CT (CBCT) scans for inter-fractional motion correction. However, real-time intra-fractional motion management is less commonly implemented. This study evaluated the extent of intra-fractional prostate motion using transperineal ultrasound (TPUS) and examined the impact of treatment time on prostate motion.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!