Clefts of the lip and/or palate (CLP) are oral-facial defects that affect health and overall quality of life. CLP patients often need multidisciplinary treatment to restore oral function and esthetics. This paper describes the oral rehabilitation of a CLP adult patient who had maxillary bone and tooth loss, resulting in decreased occlusal vertical dimension. Functional and cosmetic rehabilitation was achieved using a maxillary removable partial denture (RPD) attached to telescopic crowns. Attachment-retained RPDs may be a cost-effective alternative for oral rehabilitation in challenging cases with substantial loss of oral tissues, especially when treatment with fixed dental prostheses and/or dental implants is not possible.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jopr.12188DOI Listing

Publication Analysis

Top Keywords

removable partial
8
partial denture
8
oral rehabilitation
8
maxillary rehabilitation
4
rehabilitation removable
4
denture attachments
4
attachments cleft
4
cleft lip
4
lip palate
4
palate patient
4

Similar Publications

Evaluation of Retentive Forces in Three Types of Removable Partial Denture Framework Materials: An In Vitro Study.

Cureus

December 2024

Dentistry, Kurdistan Higher Council of Medical Specialties, Erbil, IRQ.

Introduction The utilization of Computer-Aided Design and Computer-Aided Manufacturing (CAD/CAM) technology in the production of polyetheretherketone (PEEK) and acetal frameworks enhances the precision and stability of partial denture frameworks. This study evaluates the retentive forces of CAD/CAM-fabricated PEEK, acetal, and cobalt-chromium (Co-Cr) frameworks in removable partial dentures (RPDs). Methods Forty-five frameworks were fabricated (15 each of PEEK, acetal, and Co-Cr) and tested for retentive forces using a universal testing machine at a crosshead speed of 5 mm/min.

View Article and Find Full Text PDF

Background: Computer-assisted learning (CAL) has the potential to enhance learning outcomes and satisfaction. However, there are limited reports in the literature that describe or evaluate the implementation of this method to promote competency-based learning in removable partial denture (RPD) design. Therefore, this study aimed to: (1) compare the effectiveness of different learning methods using a 3D software-aided RPD design program, (2) evaluate the learning outcomes associated with these different methods following active learning, and (3) assess students' satisfaction.

View Article and Find Full Text PDF

Objectives: To assess the effect of occlusion and implant number/position on stress distribution in Kennedy Class II implant-assisted removable partial denture (IARPD).

Materials And Methods: IARPDs were designed in six models: with one implant (bone level with a platform of 4 mm and length of 10 mm) at the site of (I) canine, (II) between first and second premolars, (III) first molar, (IV) second molar, or two implants at the sites of (V) canine-first molar, and (VI) canine-second molar. A conventional RPD served as control.

View Article and Find Full Text PDF

The influence of prosthetic treatments and implant-supported prostheses on posterior mandibular ridge atrophy: a retrospective cohort study.

BMC Oral Health

January 2025

Division of Restorative Dentistry, Periodontology and Prosthodontics, Department of Dental Medicine and Oral Health, Medical University of Graz, Billrothgasse 4, Graz, 8010, Austria.

Aims: Bone preservation is a requirement for long-term stability of dental prostheses, which is all the more important in the posterior mandible, given the particular challenges these areas pose to prosthetic treatment. The objective was to investigate the implications of different prostheses on the atrophy of posterior alveolar bone after tooth loss.

Materials And Methods: A total of 457 treatment cases were retrieved from the medical documentation and information network.

View Article and Find Full Text PDF

Purpose: This retrospective clinical study aimed to evaluate the clinical outcomes of surveyed monolithic computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia crowns for abutment teeth in removable partial dentures (RPDs).

Methods: Patients who received monolithic surveyed zirconia crowns were clinically examined. The crowns were examined according to the modified United States Public Health Service criteria, and Kaplan-Meier survival was determined.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!