Objectives: To study the healing of defects around titanium implants filled with biphasic calcium phosphates (BCP).

Material And Methods: Forty custom-made, titanium implants (Ti) with a diameter of 5 mm, and length of 8 mm, with two-sided gaps, were fabricated and installed in the femoral condyle of 20 rabbits. Following a randomization protocol, implants were alternately installed in one condyle without BCP bone substitute material (Ti) in the gaps and in the contralateral condyle gaps were filled with BCP bone substitute material (Ti+BCP). The implants were retrieved after 4 and 12 weeks of healing, after which histological and histomorphometrical analyses were done to assess the percentage of bone implant contact (BIC), the percentage of bone area (BA) and the percentage of particle area (PA) within the region of interest (ROI); the rectangular area joining the two arms of the L-shaped implant was considered as the ROI.

Results: After 4 and 12 weeks of healing, Ti+BCP showed significantly higher BIC and BA values compared to Ti. Further, the BCP particles showed a significant decrease from 4 to 12 weeks of healing. The BCP particles (PA) showed a significant reduction from 31.6 ± 11.0% at 4 weeks to 21.0 ± 7.2% at 12 weeks.

Conclusion: The addition of BCP bone substitute to fill peri-implant gaps significantly enhanced both bone formation (~2.5-fold) and bone to implant contact (>2-fold) for the custom-made titanium implants with two-sided gaps.

Download full-text PDF

Source
http://dx.doi.org/10.1111/clr.12435DOI Listing

Publication Analysis

Top Keywords

titanium implants
16
bcp bone
12
bone substitute
12
12 weeks healing
12
bone
8
custom-made titanium
8
two-sided gaps
8
substitute material
8
percentage bone
8
bone implant
8

Similar Publications

Aim: To evaluate in vitro the antibacterial efficacy and cytocompatibility of different implant-decontamination methods, using both 2D and 3D peri-implant mucosa models.

Methods: Four decontamination methods [chlorhexidine (CHX), electrolytic treatment (GS), curcumin (CUR), xanthohumol (XN)] were compared in four independent experiments, three with a 2D peri-implant mucosa model on titanium surfaces and another on a 3D peri-implant mucosa model. These decontamination procedures were tested for their antibacterial effect using a multispecies biofilm model with Streptococcus oralis, Actinomyces naeslundii, Veillonella dispar, and Porphyromonas gingivalis for 24 h.

View Article and Find Full Text PDF

Jawline improvement using patient-specific angle implants with virtual planning in orthognathic surgery.

J Craniomaxillofac Surg

January 2025

Department of Oral and Maxillo-Facial Surgery, Head and Neck Institute, University Hospital Center of Nice, 31 avenue de Valombrose, 06100, Nice, France; Nice Côte d'Azur Clinical Research Unit (UR2CA), France. Electronic address:

There has been a recent increase in the global demand for jawline augmentation. Managing angle definition in patients undergoing orthognathic surgery remains challenging owing to the characteristics of classic mandibular osteotomy, which mostly allows sagittal mandibular movements but cannot modify the ramus height. The advent of computer-assisted surgical planning and computer-aided design/computer-aided manufacturing techniques for patient-specific implant fabrication has introduced new methods for jawline management.

View Article and Find Full Text PDF

Background/purpose: Peri-implantitis remains a substantial challenge. This study investigated the effect of titanium particles on human oral epithelial cells, focusing on the nucleotide-binding domain and leucine-rich repeat protein (NLRP) 3 inflammasome.

Materials And Methods: The Ca9-22 human gingival epithelial cell line was subjected to incubation with titanium particles.

View Article and Find Full Text PDF

Background/purpose: Early osseointegration of titanium (Ti) dental implants relies on the surface topography. Surface modification of Ti seeks to enhance bone regeneration around implants. Acid etching is the simple, less technique sensitive and cost-effective technique for surface treatment.

View Article and Find Full Text PDF

Purpose: Screw-retained implant crowns are a common solution to rehabilitate single or multiple edentulous sites. Angulated screw channel (ASC) abutments have been developed as a new system of connection to correct the angulation of the implant and avoid a possible undesired emergence of the access hole. The purpose of this systematic review was to examine available literature related to the effects of ASC abutments in rehabilitating single implant crowns.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!