Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: To compare five inverse treatment planning methods with the conventional manually optimized planning approach for brachytherapy of cervical cancer with respect to dosimetric parameters.
Material And Methods: Eighteen cervical cancer patients treated with magnetic resonance imaging (MRI)-guided high dose rate (HDR) brachytherapy were included in this study. Six plans were created for each of the 4 HDR brachytherapy fractions for each patient: 1 manually optimized and 5 inversely planned. Three of these were based on inverse planning simulated annealing (IPSA) with and without extra constraints on maximum doses of the target volume, and different constraints on doses to the organs at risk (OARs). In addition there were two plans based on dose to target surface points. The resulting dose-volume histograms were analyzed and compared from the dosimetric point of view by quantifying specific dosimetric parameters, such as clinical target volume (CTV) D₉₀, CTV D₁₀₀, conformal index (COIN), and D₂cm3 for rectum, bladder and the sigmoid colon.
Results: Manual optimization led to a mean target coverage of 78.3% compared to 87.5%, 91.7% and 82.5% with the three IPSA approaches (p < 0.001). Similar COIN values for manual and inverse optimization were found. The manual optimization led to better results with respect to the dose to the OARs expressed as D₂cm3. Overall, the best results were obtained with manual optimization and IPSA plans with volumetric constraints including maximum doses to the target volume.
Conclusions: Dosimetric evaluation of manual and inverse optimization approaches is indicating the potential of IPSA for brachytherapy of cervical cancer. IPSA with constraints of maximum doses to the target volume is closer related to manual optimization than plans with constraints only to minimum dose to the target volume and maximum doses to OARs. IPSA plans with proper constraints performed better than those based on dose to target surface points and manually optimized plans.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3109/0284186X.2014.928829 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!