Background And Aim: Dobutamine stress echocardiography (DSE) is a well-established noninvasive stress modality for the detection and evaluation of coronary artery disease in diabetic patients. High-sensitivity cardiac troponin T recently emerged as a highly sensitive dosage for the detection of ischemia. The aim of the study was to examine whether high-sensitivity cardiac troponin T may improve the diagnostic accuracy of silent ischemia by DSE in high-risk diabetic patients.

Methods And Results: Twenty-one patients with long-standing (>10years) and/or complicated type II DM but no established CAD were included. In addition to DSE, venous blood samples for measurement of hs-cTnT were collected prior to DSE, 6hours and 24hours after the test. Troponins were deemed positive if>1.5 upper limit for normality. Patients with positive troponins underwent coronary angiography or CT scan regardless of the result of DSE. Among the 21 patients, 7 had positive troponins measured 6hours after stress, (mean peak troponin=44.5). DSE were negative in all of them. Mean age was 64years significantly higher than patients with negative troponins. No differences were noted between the groups in terms of epidemiological, clinical or echocardiographic characteristics. Patients with positive cardiac troponins were evaluated for the presence of coronary lesions but none of them had significant disease. After an 18-month mean follow-up, no adverse cardiac events were noted in either group.

Conclusion: In high-risk diabetic patients, the measurement of hs-cTnT during DSE does not improve the sensitivity at least in those with negative DSE tests.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ancard.2014.05.015DOI Listing

Publication Analysis

Top Keywords

high-sensitivity cardiac
12
high-risk diabetic
12
patients positive
12
cardiac troponins
8
improve diagnostic
8
diagnostic accuracy
8
dobutamine stress
8
stress echocardiography
8
dse
8
diabetic patients
8

Similar Publications

Surface-enhanced Raman spectroscopy (SERS) is widely recognized as a powerful analytical technique, offering molecular identification by amplifying characteristic vibrational signals, even at the single-molecule level. While SERS has been successfully applied for a wide range of targets including pesticides, dyes, bacteria, and pharmaceuticals, it has struggled with the detection of molecules with inherently low Raman scattering cross-sections. Urea, a key nitrogen-containing biomolecule and the diamide of carbonic acid, is a prime example of such a challenging target.

View Article and Find Full Text PDF

Objective: To assess the extent to which the concomitant presence of subclinical myocardial injury or stress and diabetes affects the risk of heart failure (HF) subtypes.

Research Design And Methods: The Jackson Heart Study included Black adults, categorized based on diabetes status, high-sensitivity cardiac troponin I (hs-cTnI), and brain natriuretic peptide (BNP) levels. Subclinical myocardial injury was defined as hs-cTnI ≥4 ng/L in women and ≥6 ng/L in men, and subclinical myocardial stress as BNP ≥35 pg/mL.

View Article and Find Full Text PDF

Analytical characteristics and performance of a new hs-cTnI method: a multicenter-study.

Clin Chem Lab Med

January 2025

Coordinator of the Italian Study Group of Cardiac Biomarkers, Scuola Superiore Sant'Anna and Fondazione CNR - Regione Toscana G. Monasterio, Pisa, Italy.

Article Synopsis
  • The study aimed to assess the performance and establish the upper reference limit for high-sensitivity cardiac troponin I (hs-cTnI) using the MAGLUMI CLIA method in healthy populations.
  • Two groups of healthy adults were analyzed: one with younger adults (average age 43) and another with older adults (average age 78), focusing on blood donation volunteers.
  • Results showed that hs-cTnI levels were significantly higher in men than women, especially after age 55, confirming that the MAGLUMI CLIA method meets international diagnostic criteria for cardiac assessments.
View Article and Find Full Text PDF

An optical biosensor is a specialized analytical device that utilizes the principles of optics and light in bimolecular processes. Localized surface plasmon resonance (LSPR) is a phenomenon in the realm of nanophotonics that occurs when metallic nanoparticles (NPs) or nanostructures interact with incident light. Conversely, surface-enhanced Raman spectroscopy (SERS) is an influential analytical technique based on Raman scattering, wherein it amplifies the Raman signals of molecules when they are situated near specific and specially designed nanostructures.

View Article and Find Full Text PDF

Genetic factors shaping the plasma lipidome and the relations to cardiometabolic risk in children and adolescents.

EBioMedicine

January 2025

Novo Nordisk Foundation Center for Basic Metabolic Research, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark. Electronic address:

Background: Lipid species are emerging as biomarkers for cardiometabolic risk in both adults and children. The genetic regulation of lipid species and their impact on cardiometabolic risk during early life remain unexplored.

Methods: Using mass spectrometry-based lipidomics, we measured 227 plasma lipid species in 1149 children and adolescents (44.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!