[Stent implantation for relief of pulmonary artery branch stenosis].

Zhonghua Er Ke Za Zhi

Department of Cardiology, Shanghai Children's Medical Center Affiliated to School of Medicine, Shanghai Jiao Tong University, Shanghai.

Published: May 2014

Objective: Branch pulmonary artery stenosis is one of the common congenital heart disease. Stent implantation to relieve branch pulmonary artery stenosis (BPAS) is an alternative to failed surgical or balloon angioplasty. The aim of this study was to explore the indication, methods and complications of using balloon expandable stent placement to treat branch pulmonary artery stenosis, and evaluate the results of stent implantation in the treatment of branch pulmonary artery stenosis.

Method: From August 2005 to December 2012, 19 patients underwent an attempt at stent implantation. The median age of those patients was 9.1 years (range 4.0-15.0 years). The median weight was 31.7 kg (range 17.0-60.5 kg); 14/19 patients underwent post surgical repair of tetralogy of Fallot, one patient received post surgical repair of pulmonary atresia with ventricular septal defect, one patient underwent post surgical repair of pulmonary atresia with intact septum, one with native left BPAS, and one was after surgical repair of aortopulmonary window and the other truncus arteriosus. CP stent and NuMED Balloon-in-Balloon catheter were selected according to digital subtracted angiography measurements. After checking for correct position by angiography, the inner balloon and outer balloon was inflated successively to expand the stent to desired diameter. Statistical analysis was performed with the unpaired Student t test.

Result: A total of 26 stents were implanted successfully in 19 patients. The systolic gradient across the stenosis fell from a median of (36.0 ± 18.3) to (3.8 ± 3.4) mmHg (P < 0.01, 1 mmHg = 0.133 kPa) and the diameter of the narrowest segment improved from (6.0 ± 1.9) to (11.6 ± 3.1) mm (P < 0.01). The right ventricle to aortic pressure ratio fell from 0.68 to 0.49 (P < 0.01). Complications included the following: two stents were malpositioned in the right ventricular outflow tract and one balloon ruptured when dilated the hole of the stent. No other complications occurred. All patients were followed up for 6 months to 6.0 (2.5 ± 1.8) years. One patient underwent stent re-dilation in order to accommodate somatic growth two years later.

Conclusion: Balloon expandable stents are safe and effective in relieving BPAS. Stent implantation should be considered the treatment of choice for most patients with BPAS. Stents placed into growing children will require further dilation to keep up with normal somatic growth. Intermediate and long-term follow up studies have shown excellent results after further dilation over time.

Download full-text PDF

Source

Publication Analysis

Top Keywords

pulmonary artery
20
branch pulmonary
16
stent implantation
16
surgical repair
16
artery stenosis
12
post surgical
12
stent
9
balloon expandable
8
patients underwent
8
underwent post
8

Similar Publications

Objectives: This retrospective study aimed to investigate the feasibility of surgical closure of ventricular septal defect in children with trisomy 18 by assessing perioperative events and long-term survival.

Methods: From April 2008 to March 2024, 41 consecutive patients were referred to us for ventricular septal defect surgery. The defect was closed in 35 patients at the end (median age, 16 months; median body weight, 5.

View Article and Find Full Text PDF

Aim: To investigate the association between Systematic Coronary Risk Evaluation 2 (SCORE2) and subclinical damage in two vascular beds: atherosclerosis in the coronary arteries and aortic arterial stiffness, in a large population-based cohort without cardiovascular disease or diabetes.

Methods: A cross-sectional study based on Swedish CArdio Pulmonary bioImaging Study (SCAPIS) data. A population-based cohort of 3087 participants aged 50-64.

View Article and Find Full Text PDF

Paradoxical embolism occurs when a clot originates in the venous system and traverses through a pulmonary or intracardiac shunt into the systemic circulation, with a mortality rate of around 18%. The risk factors for arterial embolism and venous thrombosis are similar, but different disease entities can lead to a hypercoagulable state of the blood, including antithrombin III (AT III) deficiency. We report the case of a 43-year-old man with a massive central pulmonary embolism with a rider embolus and concomitant aortic arch embolism with involvement of the brachiocephalic trunk, bilateral subclavian and axillary arteries, and the right vertebral artery, followed by a secondary ischaemic stroke.

View Article and Find Full Text PDF

Hospitalisation for acute decompensated heart failure (HF) portends a poor prognosis. Fluid retention manifesting in dyspnoea and oedema are important clinical features of decompensated heart failure and drive hospital admissions. Intracardiac and pulmonary artery pressure (PAP) monitoring can help predict heart failure decompensation, as changes in these haemodynamics occur before clinical congestion manifests.

View Article and Find Full Text PDF

Objectives: The impact of long-term complications after robotic hybrid coronary revascularization (HCR), including persistent angina, repeat revascularization, and myocardial infarction (MI), remains limited. This study aims to determine the risk factors for coronary events after robotic HCR and their time-varying effects on outcomes.

Methods: We identified all consecutive patients who underwent robotic HCR at our institution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!