Study Design: All parameters were measured manually and with a computed tomography (CT) scanner. For the manual measurements, a Vernier scale instrument was used.

Purpose: This study evaluates quantitatively pedicles of middle and lower cervical spine (C3 to C7) and to evaluate the possibilities of using these structures as anchors in posterior cervical fusion.

Overview Of Literature: Pedicle screws may be an alternative fixation technique for posterior cervical instrumentation.

Methods: Twenty-two bony sets of adult cervical spines were studied (110 vertebrae, 220 pedicles) from C3 down to C7.

Results: CT measurement of cervical pedicles appeared to be accurate and valuable for preoperative planning of cervical pedicle screw instrumentation. The study showed a high correlation between the values obtained by manual and CT measurements of pedicle dimensions. The technical challenge of insertion is the obvious theoretical drawback of the use of cervical pedicle screws. Many technical factors are important to consider, namely, the point of screw entry, the pedicle dimensions, the screw direction according to the pedicle angle and orientation, the screw diameter and length, and the method of screw introduction.

Conclusions: Transpedicular screw fixation of the cervical spine appears to be promising. Anatomic limitations should be clear to the surgeon. Further clinical and biomechanical studies are needed to settle this technique.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4068847PMC
http://dx.doi.org/10.4184/asj.2014.8.3.273DOI Listing

Publication Analysis

Top Keywords

cervical pedicle
12
cervical
9
pedicle screw
8
screw fixation
8
manual measurements
8
cervical spine
8
posterior cervical
8
pedicle screws
8
pedicle dimensions
8
screw
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!