Performance of the Liaison XL Murex HIV Ab/Ag test on clinical samples representing current epidemic HIV variants.

J Clin Microbiol

Laboratoire de Virologie Associé au Centre National de Référence du VIH, Hôpital Charles Nicolle, CHU de Rouen, Rouen, France GRAM, Equipe d'Accueil 2656, Faculté de Médecine-Pharmacie, Institut de Recherche et d'Innovation en Biomédecine, Université de Rouen, Rouen, France

Published: September 2014

Screening for HIV infection has improved since the first immunoassays. Today, diagnosis of HIV infection can be performed with fourth-generation tests that track both the patient's antibodies and HIV antigen. The objective of this study was to evaluate the clinical sensitivity and specificity of the new DiaSorin Liaison XL Murex HIV Ab/Ag assay compared to another fourth-generation assay, the Abbott Architect HIV Ag/Ab Combo kit. This work was performed on a large panel of 900 samples, including negative samples (n = 493) and HIV-positive (n = 407) representatives of HIV-1 group M subtypes and circulating recombinant forms (CRFs), HIV-1 group O, and HIV-2 variants. The results highlight the high specificity (98.9%) and sensitivity (100%) of this new fourth-generation assay, which are consistent with its use for the screening and diagnosis of HIV infections with the current circulating strains.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4313141PMC
http://dx.doi.org/10.1128/JCM.01089-14DOI Listing

Publication Analysis

Top Keywords

liaison murex
8
hiv
8
murex hiv
8
hiv ab/ag
8
hiv infection
8
diagnosis hiv
8
fourth-generation assay
8
hiv-1 group
8
performance liaison
4
ab/ag test
4

Similar Publications

Background And Objective: Serological screening for Chagas disease (CD) in Latin American adults living in Europe is a cost-effective strategy for transmission prevention. The World Health Organization recommends two different serological tests including native and recombinant antigens for IgG detection. In Spain, most commercialized native tests require manual processing.

View Article and Find Full Text PDF
Article Synopsis
  • - This study compares the effectiveness of four different tests for detecting Hepatitis E virus (HEV) antibodies: LIAISON MUREX, VIRCLIA, WANTAI, and VIDAS.
  • - All tests showed 100% sensitivity for detecting anti-HEV IgM in the acute phase, but there were variations in their sensitivity and specificity during later phases of infection.
  • - LIAISON MUREX performed the best overall, especially for detecting acute HEV infections and providing accurate results for anti-HEV IgG antibodies.
View Article and Find Full Text PDF

Assessment of the Diagnostic Performance of Fully Automated Hepatitis E Virus (HEV) Antibody Tests.

Diagnostics (Basel)

March 2024

Labor Dr. Krause und Kollegen MVZ GmbH, Steenbeker Weg 23, D-24106 Kiel, Germany.

The detection of anti-hepatitis E virus (HEV) antibodies contributes to the diagnosis of hepatitis E. The diagnostic suitability of two automated chemiluminescence immunoassays (CLIAs, LIAISON MUREX Anti-HEV IgG/Anti-HEV IgM test, DiaSorin) was assessed by comparison with the results of a combination of enzyme immunoassays and immunoblots (Well HEV IgG/IgM ELISA, Line HEV IgG/IgM, MIKROGEN). Samples with a deviating result were analyzed with the WANTAI ELISAs.

View Article and Find Full Text PDF

A transversal study was conducted among 472 vulnerable individuals (recyclable waste pickers, immigrants and refugees, homeless individuals, as well as lesbian, gay, bisexual, and transexual individuals) in Goiânia City, the capital of the State of Goiás, Brazil, to investigate the prevalence of hepatitis E virus (HEV) infection. A total of 459 (97.2%) serum samples were tested for anti-HEV IgG and IgM antibodies using fully automated chemiluminescence immunoassays (Liaison Murex Anti-HEV IgG and IgM assays, DiaSorin, Saluggia, Italy).

View Article and Find Full Text PDF

Background And Aims: The prevalence of HDV infection in HBsAg carriers is about 9.9% in Italy. However, the real prevalence is underestimated because the anti-HDV test is not performed routinely in all HBsAg carriers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!