Candida keratitis after Descemet stripping with automated endothelial keratoplasty.

Eur J Ophthalmol

Corneal and external diseases department, Institute of Ophthalmology "La Arruzafa", Córdoba - Spain.

Published: December 2014

Purpose: To report a case of Candida albicans keratitis after Descemet stripping with automated endothelial keratoplasty (DSAEK) due to fungal contamination of the donor cornea.

Methods: Case report.

Results: A 73-year-old woman underwent phacoemulsification with intraocular lens (IOL) implantation and DSAEK with 1 week difference. Ten days after DSAEK surgery, the culture of the donor corneoscleral rim revealed Candida albicans contamination and a small whitish infiltrate was noted within the interface. Despite conservative treatment with oral and systemic voriconazole, the infection was present outside the interface and inside the anterior chamber. Hot penetrating keratoplasty (PKP) was performed and the infection was eradicated. However, due to uncontrolled high intraocular pressure, a new PKP had to be performed, the IOL was removed, and an Ahmed valve was implanted (by pars plana vitrectomy). The anterior cap of the same donor cornea was used to perform a tectonic superficial anterior lamellar keratoplasty and the recipient did not have any problem related to fungal infection.

Conclusions: The diagnosis of fungal keratitis should be taken into account once a small infiltrate is seen in the interface of any kind of lamellar keratoplasty. It is not clear whether it is better to treat it conservatively or aggressively.

Download full-text PDF

Source
http://dx.doi.org/10.5301/ejo.5000499DOI Listing

Publication Analysis

Top Keywords

keratitis descemet
8
descemet stripping
8
stripping automated
8
automated endothelial
8
endothelial keratoplasty
8
candida albicans
8
infiltrate interface
8
pkp performed
8
lamellar keratoplasty
8
keratoplasty
5

Similar Publications

Purpose: Anterior segment optical coherence tomography (AS-OCT) is increasingly being used to complement slit-lamp biomicroscopy in the evaluation of corneal infections. Our purpose was to analyze, compare, and correlate the clinical signs elicited by these 2 methods in patients with infectious keratitis (IK).

Methods: Slit-lamp photomicrographs (diffuse and slit beam) and AS-OCT scans were obtained from 20 consecutive patients (21 eyes) with IK.

View Article and Find Full Text PDF

Background: Corneal pathologies are among the most common reversible sight-threatening diseases globally. As such, corneal tissue transplantation (keratoplasty) techniques are evolving over time depending on the prevalence of different pathologies in each geographical area. We aim to provide a baseline information on the common keratoplasty procedures performed in our area in relation to prevalent corneal pathologies and to analyze common corneal surgical practice trends in our area.

View Article and Find Full Text PDF

Purpose: To highlight the rarity of the endothelial rejection line, also known as the Khodadoust line, as a manifestation following Descemet's stripping automated endothelial keratoplasty (DSAEK). The objective is to present a meticulously detailed case, including imaging and anterior optical coherence tomography (OCT), to enhance understanding and recognition of this phenomenon.

Methods: A detailed case presentation involving a 50-year-old male, 3 years post-DSAEK transplantation for endothelial damage resulting from intraocular surgeries.

View Article and Find Full Text PDF

Purpose: To report the demographic profile, clinical characteristics, risk factors and outcomes of graft rejection after DSEK.

Methods: A total of 3073 eyes had DSEK between 2012 and 2019, of which 1710 eyes that had follow up of more than one year. Sixty-one eyes who had graft rejection during this period were studied.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!