Outbreaks of Legionnaires' disease require environmental testing of water samples from potentially implicated building water systems to identify the source of exposure. A previous study reports a large impact on Legionella sample results due to shipping and delays in sample processing. Specifically, this same study, without accounting for measurement error, reports more than half of shipped samples tested had Legionella levels that arbitrarily changed up or down by one or more logs, and the authors attribute this result to shipping time. Accordingly, we conducted a study to determine the effects of sample holding/shipping time on Legionella sample results while taking into account measurement error, which has previously not been addressed. We analyzed 159 samples, each split into 16 aliquots, of which one-half (8) were processed promptly after collection. The remaining half (8) were processed the following day to assess impact of holding/shipping time. A total of 2544 samples were analyzed including replicates. After accounting for inherent measurement error, we found that the effect of holding time on observed Legionella counts was small and should have no practical impact on interpretation of results. Holding samples increased the root mean squared error by only about 3-8%. Notably, for only one of 159 samples, did the average of the 8 replicate counts change by 1 log. Thus, our findings do not support the hypothesis of frequent, significant (≥= 1 log10 unit) Legionella colony count changes due to holding.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2014.05.025DOI Listing

Publication Analysis

Top Keywords

measurement error
16
holding time
8
water samples
8
legionella sample
8
holding/shipping time
8
159 samples
8
samples
7
legionella
6
time
5
error
5

Similar Publications

Purpose: To identify the minimally required number of distances of visual acuity (VA) measurements for the reliable estimation of the visual acuity curve (VAC) and area of the curve (AoC) in presbyopia correction.

Patients And Methods: The study was divided into a validation and a clinical phase with a total recruitment of 120 participants (120 eyes) who underwent uncomplicated pseudophakic presbyopia surgery with bilateral premium intraocular lenses (IOL) implantation. This study was conducted in the Department of Ophthalmology, University Hospital of Alexandroupolis, Alexandroupolis, Greece.

View Article and Find Full Text PDF

To introduce ABBA Letter Alternation (ABBA) as a computerized measure of response inhibition/response alternation developed for telehealth following restrictions of in-person testing due to COVID-19. ABBA consists of two PowerPoint-administered trials: Letter Reading of 25 capital As or Bs individually presented, and Letter Alternation with instructions to say the opposite letter to what is presented. We obtained initial normative ABBA performance from 899 healthy research volunteers participating in the Emory Healthy Brain Study (EHBS) with Montreal Cognitive Assessment (MoCA) scores 24/30 and higher.

View Article and Find Full Text PDF

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

JMIR Mhealth Uhealth

January 2025

ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.

Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.

View Article and Find Full Text PDF

Background: Improving functioning in adults with major depressive disorder (MDD) and bipolar disorder (BD) is a priority therapeutic objective.

Methods: This retrospective post hoc secondary analysis evaluated 108 patients with MDD or BD receiving the antidepressants vortioxetine, ketamine, or infliximab. The analysis aimed to determine if changes in objective or subjective cognitive function mediated the relationship between depression symptom severity and workplace outcomes.

View Article and Find Full Text PDF

Objective: Propose a framework to empirically evaluate and report validity of findings from observational studies using pre-specified objective diagnostics, increasing trust in real-world evidence (RWE).

Materials And Methods: The framework employs objective diagnostic measures to assess the appropriateness of study designs, analytic assumptions, and threats to validity in generating reliable evidence addressing causal questions. Diagnostic evaluations should be interpreted before the unblinding of study results or, alternatively, only unblind results from analyses that pass pre-specified thresholds.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!