Since the inception of root form implant dentistry by P-I Branemark in the early 1980's, so many technical advances have been put forward by several authors. However, the open tray impression technique is still performed for impressing multiple implant fixtures as it was first described in the original Branemark procedure manual. The most critical aspect for a successful implant-supported restoration is the passive and an accurate fit of superstructures to avoid preload and loading stresses. Splinting impression technique in multiple implants has gained popularity. Auto-polymerizing acrylic resin is among the most routinely practiced splinting material for multiple implant units. However, unfortunately, it exhibits shrinkage, which makes an impression quite inaccurate. This case report presents the solution to minimize the shrinkage of resin by utilizing sectional-splinting technique as advocated in the previous implant literature.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4067788PMC
http://dx.doi.org/10.4103/0976-237X.132347DOI Listing

Publication Analysis

Top Keywords

multiple implant
12
sectional-splinting technique
8
impressing multiple
8
implant units
8
open tray
8
impression technique
8
implant
5
technique impressing
4
multiple
4
units eliminating
4

Similar Publications

Background: Catecholaminergic polymorphic ventricular tachycardia (CPVT) is a rare inherited arrhythmia disorder characterized by ventricular arrhythmia triggered by adrenergic stimulation.

Case Presentation: A 9-year-old boy presented with convulsions following physical exertion. Bidirectional ventricular tachycardia (VT) during a treadmill test led to the diagnosis of catecholaminergic polymorphic ventricular tachycardia (CPVT).

View Article and Find Full Text PDF

Total femoral replacement (TFR) is not a common surgery and most indications are for oncological pathologies. However, there are few instances where non-oncological indications might necessitate TFR; this may be a salvage surgery for failed previous hip and/or knee surgeries with consequent significant femur bone loss. We present a 59-year-old obese woman with right thigh pain and difficulty with walking of 5 years duration.

View Article and Find Full Text PDF

PreVISE: an efficient virtual reality system for SEEG surgical planning.

Virtual Real

December 2024

Department of Computer Science and Software Engineering, Concordia University, Montreal, Québec Canada.

Epilepsy is a neurological disorder characterized by recurring seizures that can cause a wide range of symptoms. Stereo-electroencephalography (SEEG) is a diagnostic procedure where multiple electrodes are stereotactically implanted within predefined brain regions to identify the seizure onset zone, which needs to be surgically removed or disconnected to achieve remission of focal epilepsy. This procedure is complex and challenging due to two main reasons.

View Article and Find Full Text PDF

Medical and advanced heart failure therapies in Türkiye.

Turk J Med Sci

December 2024

Deputy Health Minister, Ministry of Health, Ankara, Turkiye.

Background/aim: Effective management of heart failure involves evidence-based use of multiple medications and their combinations. Furthermore, dosage escalation of the recommended medications is advised. In cases of advanced heart failure, long-term mechanical assistance devices or heart transplantation surgery may be necessary.

View Article and Find Full Text PDF

Design of a versatile platform on nanostructured Ti-Mo-Zr alloy surface with photothermal, antibacterial and osteoinductive properties for biomedical application.

Colloids Surf B Biointerfaces

December 2024

School of Materials and Physics, China University of Mining and Technology, Xuzhou 221116, PR China; School of Materials Science and Engineering, Jiangsu Key Laboratory for Advanced Metallic Materials, Southeast University, Nanjing 2211189, PR China. Electronic address:

Bacterial infection and inadequate osseointegration represent significant challenges in the application of titanium (Ti)-based bone implants. Surface modification presents a promising strategy to address these obstacles. Taking advantage of silver ions, black phosphorus nanosheets (BPNs) and polydopamine (PDA), this study developed a versatile platform on the surface of Ti-12Mo-10Zr (TMZ) alloy through a multiple surface modification process, including the anodic oxidation treatment of TMZ alloy, the preparation and addition of silver-loaded BPNs (BPNs/Ag), and the coating with PDA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!