Nickel (II) preconcentration and speciation analysis using a hollow fiber supported liquid membrane (HFSLM) device was studied. A counterflow of protons coupled to complexation with formate provided the driving force of the process, while Kelex 100 was employed as carrier. The influence of variables related to module configuration (acceptor pH and carrier concentration) and to the sample properties (donor pH) on the preconcentration factor, E, was simultaneously studied and optimized using a 3 factor Doehlert matrix response surface methodology. The effect of metal concentration was studied as well. Preconcentration factors as high as 4240 were observed depending on the values of the different variables. The effects of the presence of inorganic anions (NO2-, SO42-, Cl-, NO3-, CO32-, CN-) and dissolved organic matter (DOM) in the form of humic acids were additionally considered in order to carry out a speciation analysis study. Nickel preconcentration was observed to be independent of both effects, except when cyanide was present in the donor phase. A characterization of the transport regime was performed through the analysis of the dependence of E on the temperature. E increases with the increase in temperature according to the equation E(K) = -8617.3 + 30.5T with an activation energy of 56.7 kJ mol-1 suggesting a kinetic-controlled regime. Sample depletion ranged from 12 to 1.2% depending on the volume of the donor phase (100 to 1000 mL, respectively).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4021897 | PMC |
http://dx.doi.org/10.3390/membranes1030217 | DOI Listing |
Molecules
December 2024
Gulbali Institute, Charles Sturt University, Wagga, NSW 2650, Australia.
The most commonly used methods to chemically assess grape and wine quality with high sensitivity and selectivity require lengthy analysis time and can be resource intensive. Here, we developed a rapid and non-destructive method that would help in grading and decision support. In this work, we demonstrate that integrating a three-dimensional (3D) material for volatile sampling with mass spectrometry detection can be used to sample grapes for phytosanitary, quality or smoke-taint assessments at low levels of marker compounds.
View Article and Find Full Text PDFEnviron Monit Assess
December 2024
Chemistry Department, Faculty of Art and Science, Yıldız Technical University, 34220, Istanbul, Türkiye.
In this study, a preconcentration strategy based on Ni(OH) nanoflowers (NFs) was developed for the extraction/separation of bismuth ions from environmental water samples before the determination by flame atomic absorption spectrometry (FAAS). The homogeneous coprecipitation method was employed for the synthesis of the flower-shaped Ni(OH) and used as an adsorbent for the preconcentration of bismuth. The extraction variables were determined by a univariate optimization strategy to obtain maximum extraction performance.
View Article and Find Full Text PDFFood Chem
March 2025
Department of Chemistry, Faculty of Sciences, Erciyes University, 38039 Kayseri, Türkiye; Technology Research & Application Center (ERU-TAUM), Erciyes University, 38039 Kayseri, Türkiye; Turkish Academy of Sciences (TUBA), Çankaya, Ankara, Türkiye. Electronic address:
A novel dispersive solid phase microextraction (dSP-ME) technique using activated carbon cloth (ACC) and layered double hydroxide (LDH) has been developed for enriching and extracting Pb(II) and Ni(II). The ACC@MnCoAl-LDH nanosorbent, has proven with high surface area, superior extraction dynamics and efficiency, compared to traditional sorbents. Structural features of the new ACC@MnCoAl-LDH sorbent were also characterized.
View Article and Find Full Text PDFEnviron Monit Assess
November 2024
Faculty of Chemistry, Brno University of Technology (BUT), Purkyňova 464/118, 612 00, Brno, Czech Republic.
A new effective method has been developed for field determination of trace concentrations of cadmium, arsenic, zinc, copper, nickel, chromium, and lead in waters (e.g., surface and wastewater) using an energy dispersive X-ray fluorescence (EDXRF) analyzer.
View Article and Find Full Text PDFJ Sep Sci
October 2024
Hainan International Joint Research Center of Marine Advanced Photoelectric Functional Materials, College of Chemistry and Chemical Engineering, Hainan Normal University, Haikou, P. R. China.
The excessive accumulation of heavy metals has adverse effects on the human body. Here, magnetic iron oxide-impregnated carboxymethyl-β-cyclodextrin was synthesized. The synthesized material was employed as a magnetic solid-phase extracting adsorbent for specific heavy metals like lead (Pb), nickel (Ni), copper (Cu), and cobalt (Co).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!