This study investigates the use of gallium (Ga) based glass polyalkenoate cements (GPCs) as a possible alternative adhesive in sternal fixation, post sternotomy surgery. The glass series consists of a Control (CaO-ZnO-SiO2), and LGa-1 and LGa-2 which contain Ga at the expense of zinc (Zn) in 0.08 mol% increments. The additions of Ga resulted in increased working time (75 s to 137 s) and setting time (113 to 254 s). Fourier Transform Infrared (FTIR) analysis indicated that this was a direct result of increased unreacted poly(acrylic acid) (PAA) and the reduction of crosslink formation during cement maturation. LGa samples (0.16 wt % Ga) resulted in an altered ion release profile, particularly for 30 days analysis, with maximum Ca2+, Zn2+, Si4+ and Ga3+ ions released into the distilled water. The additions of Ga resulted in increased roughness and decreased contact angles during cement maturation. The presence of Ga has a positive effect on the compressive strength of the samples with strengths increasing over 10 MPa at 7 days analysis compared to the 1 day results. The additions of Ga had relatively no effect on the flexural strength. Tensile testing of bovine sterna proved that the LGa samples (0.16 wt % Ga) are comparable to the Control samples.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4030933 | PMC |
http://dx.doi.org/10.3390/jfb4040329 | DOI Listing |
J Biomech
December 2024
Toronto Metropolitan University, Department of Biomedical Engineering, Canada. Electronic address:
Adhesive-augmented sternal fixation (AASF) has been investigated as an alternative to the clinical standard of cerclage wires; however, previous studies have focused on a full adhesive layer across the sternal midline, which acts as a barrier to bone healing. This study used a human cadaveric model to investigate if partial coverage AASF used in combination with wired fixation could provide adequate stability. Median sternotomies were performed on fifteen human cadaveric sterna.
View Article and Find Full Text PDFJ Biomater Appl
October 2024
Department of Chemical and Biochemical Engineering, Missouri University of Science and Technology, Rolla, MO, USA.
Lidocaine hydrochloride is used as an anesthetic for clinical applications. This study considers the effects of the substitution of 2% lidocaine hydrochloride for deionized (DI) water on the rheological, mechanical, ion release, pH and injectable properties of two formulations of aluminum-free glass polyalkenoate cements (GPCs) using two distinct poly(acrylic) acids (PAA), E9 and E11, which have different molecular weights (Mw). The substitution of 2% lidocaine hydrochloride demonstrated increased injectability, but did not affect mechanical properties.
View Article and Find Full Text PDFBiomed Mater
July 2024
Department of Chemical & Biochemical Engineering, Missouri S&T, Rolla, MO, United States of America.
Metastatic bone lesions are often osteolytic, which causes advanced-stage cancer sufferers to experience severe pain and an increased risk of developing a pathological fracture. Gallium (Ga) ion possesses antineoplastic and anti-bone resorption properties, suggesting the potential for its local administration to impede the growth of metastatic bone lesions. This study investigated the chemotherapeutic potential, cytotoxicity, and osteogenic effects of a Ga-doped glass polyalkenoate cement (GPC) (C-TA2) compared to its non-gallium (C-TA0) counterpart.
View Article and Find Full Text PDFCureus
March 2024
Nanobiomedicine Lab, Centre for Global Health Research, Saveetha Medical College and Hospital, Saveetha Institute of Medical and Technical Sciences, Chennai, IND.
Background and objective Glass ionomer cement (GIC), also known as polyalkenoate cement, has been extensively used in dentistry for both luting and restorative purposes. Despite being the first choice for aesthetic restorations due to their chemical bonding ability to teeth, GICs have faced challenges such as low mechanical properties, abrasion resistance, and sensitivity to moisture, leading to the search for improved materials. This study aims to assess the effects of thermocycling on the compressive, flexural strength, and microhardness of green-mediated nanocomposite-modified GIC in comparison to traditional GIC.
View Article and Find Full Text PDFHeliyon
February 2024
Department of Biomaterials and Experimental Dentistry, Poznań University of Medical Sciences, Ul. Bukowska 70, 60-812 Poznań, Poland.
Objectives: This paper reviews the chemical behaviour of glass polyalkenoate (glass-ionomer) dental cements, both conventional and resin-modified, in contact with natural tissues, with the aim of determining whether these materials can be considered to be bioactive.
Data: Relevant papers describing the behaviour of bioactive glasses and ceramics, and glass-ionomer (glass polyalkenoate) cements have been identified using PubMed and Science Direct. This has allowed a comparison to be made between the behaviour of glass-ionomers and the speciality glasses and ceramics that are widely classified as bioactive, a designation considered valid for over fifty years.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!