Background: In order to rapidly and efficiently screen potential biofuel feedstock candidates for quintessential traits, robust high-throughput analytical techniques must be developed and honed. The traditional methods of measuring lignin syringyl/guaiacyl (S/G) ratio can be laborious, involve hazardous reagents, and/or be destructive. Vibrational spectroscopy can furnish high-throughput instrumentation without the limitations of the traditional techniques. Spectral data from mid-infrared, near-infrared, and Raman spectroscopies was combined with S/G ratios, obtained using pyrolysis molecular beam mass spectrometry, from 245 different eucalypt and Acacia trees across 17 species. Iterations of spectral processing allowed the assembly of robust predictive models using partial least squares (PLS).

Results: The PLS models were rigorously evaluated using three different randomly generated calibration and validation sets for each spectral processing approach. Root mean standard errors of prediction for validation sets were lowest for models comprised of Raman (0.13 to 0.16) and mid-infrared (0.13 to 0.15) spectral data, while near-infrared spectroscopy led to more erroneous predictions (0.18 to 0.21). Correlation coefficients (r) for the validation sets followed a similar pattern: Raman (0.89 to 0.91), mid-infrared (0.87 to 0.91), and near-infrared (0.79 to 0.82). These statistics signify that Raman and mid-infrared spectroscopy led to the most accurate predictions of S/G ratio in a diverse consortium of feedstocks.

Conclusion: Eucalypts present an attractive option for biofuel and biochemical production. Given the assortment of over 900 different species of Eucalyptus and Corymbia, in addition to various species of Acacia, it is necessary to isolate those possessing ideal biofuel traits. This research has demonstrated the validity of vibrational spectroscopy to efficiently partition different potential biofuel feedstocks according to lignin S/G ratio, significantly reducing experiment and analysis time and expense while providing non-destructive, accurate, global, predictive models encompassing a diverse array of feedstocks.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4064109PMC
http://dx.doi.org/10.1186/1754-6834-7-93DOI Listing

Publication Analysis

Top Keywords

s/g ratio
12
validation sets
12
lignin syringyl/guaiacyl
8
mid-infrared near-infrared
8
near-infrared raman
8
raman spectroscopies
8
potential biofuel
8
vibrational spectroscopy
8
spectral data
8
spectral processing
8

Similar Publications

The inherent heterogeneity, poor compatibility with polymers, and dark color of lignin limit its application in composites. In this study, original lignin (OL) was fractionated sequentially using four green organic solvents to obtain lignin fractions with different chemical structures. These well-defined lignin fractions were then blended with polybutylene succinate (PBS) to fabricate biocomposites.

View Article and Find Full Text PDF

The cyclic triangular complex - silver (I) 4-nitro-3,5-bis(trifluoromethyl)pyrazolate (Agpz) with super π-acidity shows great potential in adsorptive desulfurization (ADS) as a novel adsorbent, however, it fails to work well in the continue flow adsorption study. In order to improve its dynamic adsorption performance, a composite has been prepared by mixing Agpz and multilayer graphene (MG) in methanol. Based on the results of characterization by FT-IR, XPS, SEM, and so on, the optimal mass ratio of Agpz:MG in the synthesis is 0.

View Article and Find Full Text PDF

Evaluation of a Deep Learning Denoising Algorithm for Dose Reduction in Whole-Body Photon-Counting CT Imaging: A Cadaveric Study.

Acad Radiol

January 2025

Department of Radiology, University Hospital Tuebingen, Hoppe-Seyler-Str. 3, 72076 Tuebingen, Germany (R.D., J.M.B., B.S., J.M., S.G., P.K., S.W., J.H., K.N., S.A., A.B.).

Rationale And Objectives: Photon Counting CT (PCCT) offers advanced imaging capabilities with potential for substantial radiation dose reduction; however, achieving this without compromising image quality remains a challenge due to increased noise at lower doses. This study aims to evaluate the effectiveness of a deep learning (DL)-based denoising algorithm in maintaining diagnostic image quality in whole-body PCCT imaging at reduced radiation levels, using real intraindividual cadaveric scans.

Materials And Methods: Twenty-four cadaveric human bodies underwent whole-body CT scans on a PCCT scanner (NAEOTOM Alpha, Siemens Healthineers) at four different dose levels (100%, 50%, 25%, and 10% mAs).

View Article and Find Full Text PDF

Impact of Endorectal Coil Use on Extraprostatic Extension Detection in Prostate MRI: A Retrospective Monocentric Study.

Acad Radiol

January 2025

Molecular Imaging Branch, National Cancer Institute, National Institutes of Health, Bethesda, MD (O.T.E., E.C.Y., B.D.S., S.A.H., D.G.G., Y.L., M.J.B., P.L.C., B.T.). Electronic address:

Rationale And Objectives: Accurate preoperative mpMRI-based detection of extraprostatic extension (EPE) in prostate cancer (PCa) is critical for surgical planning and patient outcomes. This study aims to evaluate the impact of endorectal coil (ERC) use on the diagnostic performance of mpMRI in detecting EPE.

Materials And Methods: This retrospective study with prospectively collected data included participants who underwent mpMRI and subsequent radical prostatectomy for PCa between 2007 and 2024.

View Article and Find Full Text PDF

Background: Achieving optimal glucose control is essential in the management of type 2 diabetes (T2D). This study aimed to evaluate the effectiveness and safety of oral quadruple combination therapy for the treatment of T2D.

Methods: This meta-analysis reviewed original research on oral quadruple combination therapy for T2D, including both experimental and observational studies with a minimum duration of 12 weeks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!