Objectives: The most important drawback of dental implant/abutment assemblies is the need for a fixing screw. This study aimed to develop an esthetic one-piece Y-TZP abutment to suppress the use of the screw.
Methods: Material characterization was performed using a bar-shaped specimen obtained by slip-casting to validate the method prior to prototype abutment fabrication by the same process. The mechanical behavior of the prototype abutment was verified and compared with a conventional abutment by finite element analysis (FEA). The abutment was evaluated by micro-CT analysis and its density was measured.
Results: FEA showed stress concentration at the first thread pitch during installation and in the cervical region during oblique loading for both abutments. However, stress concentration was observed at the base of the screw head and stem in the conventional abutment. The relative density for the fabricated abutment was 95.68%. Micro-CT analysis revealed the presence of elongated cracks with sharp edges over the surface and porosity in the central region.
Significance: In the light of these findings, the behavior of a one-piece abutment is expected to be better than that of the conventional model. New studies should be conducted to clarify the performance and longevity of this one-piece Y-TZP abutment.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.dental.2014.05.016 | DOI Listing |
Beijing Da Xue Xue Bao Yi Xue Ban
August 2023
Department of Proshodontics, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices & Beijing Key Laboratory of Digital Stomatology, Beijing 100081, China.
Objective: To evaluate the effects of surface treatment on the phase and fracture strength of yttria-and magnesia-stabilized and its mechanisms.
Methods: One-piece cylindrical screw-type implants were fabricated with yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and magnesia partially stabilized zirconia (Mg-PSZ) using computer aided design (CAD)/computer aided manufacture (CAM) technique.They were divided into three groups: (1) placed in water for 1 h after final sintering (control group), (2) sandblasting using 110 μm AlO particles, (3) sandblasting plus etching with hydrofluoric acid for 1 h.
Int J Oral Maxillofac Implants
April 2023
To evaluate the 15-year survival rate of zirconia (Y-TZP) implants with a roughened acid-etched surface in a retrospective post-market clinical follow-up (PMCF) study. One-piece ceramic implants (CeraRoot) with a roughened acid-etched surface (ICE) were used. Six different implant shapes/sizes were used in this study.
View Article and Find Full Text PDFDent Mater J
July 2021
Department of Oral and Maxillofacial Implantology, Tokyo Dental College.
The objective of this study was to clarify the fatigue behavior of hollow yttria-stabilized tetragonal zirconia polycrystals (Y-TZP) specimens assuming its use for two-piece implants. The fatigue properties of a solid specimen (which simulated a one-piece implant) and 3 types of hollow specimens (which simulated two-piece implants) were evaluated. Specimens were either solid with a diameter of 4.
View Article and Find Full Text PDFClin Cosmet Investig Dent
July 2018
Division of Biomaterials and Prosthodontics Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand.
Objective: This investigation determined the internal precision of one-piece cross-arch yttria partially stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramic fabricated from two digital systems (Trios-3 and CS-3500) compared to traditional metal alloy casting.
Materials And Methods: A metal model consisting of four abutments (two canine and two molar) was used for one-piece cross-arch reconstruction. The metal abutments were computerized, prepared in a cylinder form possessing 5° taper and chamfer margin.
J Mech Behav Biomed Mater
August 2018
Department of Prosthodontics, Peking University School and Hospital of Stomatology, 22 South Street ZhongGuanCun, Haidian District, Beijing 100081, China.
Objectives: The effects of different surface treatments on cyclic fatigue strengths of computer-aided design and computer-aided manufacturing (CAD/CAM) zirconia implants and its mechanisms were evaluated.
Material And Methods: One-piece cylindrical screw-type zirconia (Y-TZP) implants with diameters of 4.1-mm were fabricated using CAD/CAM technique; they were divided into four groups according to the type of surface treatment: (i) sintering (control group, CTRL), (ii) sandblasting (SB), (iii) sandblasting and etching with an experimental hot etching solution (SB-ST), and (iv) sandblasting and etching with hydrofluoric acid (SB-HF).