Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate the safety and long-term durability of 1-stage repair of enteric fistulas in the presence of an abdominal wall defect.
Background: Patients with enteric fistulas and an abdominal wall defect present an extreme challenge to surgeons and have been associated with significant morbidity and mortality. Durability of repair is unknown as studies fail to report this or use limited follow-up periods.
Methods: Chart review was done of consecutive patients who underwent 1-stage repair. Short-term outcomes included morbidity (wound and medical) and mortality. Long-term durability of repair was determined by prospective outpatient follow-up at least 3 years after surgery.
Results: Thirty-nine patients were included with a mean age of 61.2 years, a mean BMI of 24.4 kg/m2, and a mean abdominal wall defect size of 247.9 cm2. Component separation technique was used in 34 (87.2%) and synthetic mesh in 13 (33.3%) patients. There was 1 (2.6%) postoperative death. Twenty-four wound complications developed in 18 (46.2%) patients, including surgical-site infection in 8 (20.5%) patients. Two (5.1%) enteric fistulas recurred and were treated conservatively resulting in closure. Medical complications were seen 36 times in 23 (59%) patients. Twelve of 33 (36.4%) living patients developed a recurrent hernia after a mean follow-up of 62.7 months (range: 36-130).
Conclusions: One-stage abdominal wall reconstruction with enteric fistula takedown is feasible at the cost of considerable morbidity. Our treatment strategy including component separation technique with synthetic mesh on-demand results in a durable repair in 6 to 7 of 10 patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SLA.0000000000000733 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!