Rapid technological improvements in radiotherapy delivery results in improved outcomes to patients, yet current commercial systems with these technologies on board are costly. The aim of this study was to develop a state-of-the-art cancer radiotherapy system that is economical and space efficient fitting with current world demands. The Nano-X system is a compact design that is light weight combining a patient rotation system with a vertical 6 MV fixed beam. In this paper, we present the Nano-X system design configuration, an estimate of the system dimensions and its potential impact on shielding cost reductions. We provide an assessment of implementing such a radiotherapy system clinically, its advantages and disadvantages compared to a compact conventional gantry rotating linac. The Nano-X system has several differentiating features from current radiotherapy systems, it is [1] compact and therefore can fit into small vaults, [2] light weight, and [3] engineering efficient, i.e., it rotates a relatively light component and the main treatment delivery components are not under rotation (e.g., DMLCs). All these features can have an impact on reducing the costs of the system. In terms of shielding requirements, leakage radiation was found to be the dominant contributor to the Nano-X vault and as such no primary shielding was necessary. For a low leakage design, the Nano-X vault footprint and concrete volume required is 17 m2 and 35 m3 respectively, compared to 54 m2 and 102 m3 for a conventional compact linac vault, resulting in decreased costs in shielding. Key issues to be investigated in future work are the possible patient comfort concerns associated with the patient rotation system, as well as the magnitude of deformation and subsequent adaptation requirements.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.7785/tcrt.2012.500436 | DOI Listing |
Cancers (Basel)
January 2025
Department of Gynaecologic Oncology, Maria Sklodowska-Curie National Research Institute of Oncology Krakow Branch, 31-115 Kraków, Poland.
Endometrial cancer (EC) incidence and mortality have been steadily rising globally over recent decades. The introduction of advanced molecular technologies, such as next-generation sequencing (NGS) alongside the FIGO 2023 classification, presents opportunities for refined diagnostics and risk stratification. This study aimed to analyze differences in EC classification among oncology centers in southeastern Poland.
View Article and Find Full Text PDFCancers (Basel)
January 2025
Canarian Insitute for Cancer Research, 380204 San Cristobal de La Laguna, Spain.
Objective: We demonstrated for the first time the safety and feasibility of escalating up to 55 Gy/11 Gy/fr/5fr in borderline (BRPC)/unresectable locally advanced pancreatic cancer (LAPC), using the standard LINAC platform. The aim of the present study is to assess for the first time the impact of this high-dose neoadjuvant stereotactic ablative radiotherapy (SABRT) protocol on tumor resectability and pathological responses.
Materials/methods: From June 2017 to December 2022, patients with BRPC/LAPC were treated with neoadjuvant chemotherapy (ChT) and SABRT-escalated doses of SIB at 45 Gy, 50 Gy, and up to 55 Gy (BED ≥ 100).
Cancers (Basel)
January 2025
Intense Laser Irradiation Laboratory, National Institute of Optics, National Research Council of Italy, 56124 Pisa, Italy.
The use of very high energy electron (VHEE) beams, with energies between 50 and 400 MeV, has drawn considerable interest in radiotherapy due to their deep tissue penetration, sharp beam edges, and low sensitivity to tissue density. VHEE beams can be precisely steered with magnetic components, positioning VHEE therapy as a cost-effective option between photon and proton therapies. However, the clinical implementation of VHEE therapy (VHEET) requires advances in several areas: developing compact, stable, and efficient accelerators; creating sophisticated treatment planning software; and establishing clinically validated protocols.
View Article and Find Full Text PDFAntioxidants (Basel)
January 2025
Key Laboratory of Birth, Defects and Related Diseases of Women and Children, Department of Gynecology and Obstetrics, Ministry of Education, West China Second Hospital, Sichuan University, Chengdu 610041, China.
Oxidative stress is a state of imbalance between the production of reactive oxygen species (ROS) and reactive nitrogen species (RNS) and the antioxidant defence system in the body. Oxidative stress may be associated with a variety of diseases, such as ovarian cancer, diabetes mellitus, and neurodegeneration. The generation of oxidative stress in ovarian cancer, one of the common and refractory malignancies among gynaecological tumours, may be associated with several factors.
View Article and Find Full Text PDFRadiother Oncol
January 2025
Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, WI 53226, United States. Electronic address:
Background: Re-irradiation in radiotherapy presents complexities that require dedicated tools to generate optimal re-treatment plans. This study presents a robust workflow that considers fractionation size, anatomical variations between treatments, and cumulative bias doses to improve the re-irradiation planning process.
Methods: The workflow was automated in MIM® Software and the Elekta© Monaco® treatment planning system.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!