Clinical image quality in daily practice of breast cancer mammography screening.

Can Assoc Radiol J

Centre de Recherche du CHU de Québec, Axe Oncologie, Québec, Québec, Canada; Département de Médecine Sociale et Préventive, Faculté de médicine and Centre de Recherche sur le cancer, Université Laval, Québec, Québec, Canada.

Published: August 2014

Objective: To assess the quality of screening mammograms performed in daily practice in the Quebec Breast Cancer Screening Program.

Subjects And Methods: Clinical image quality of a random subsample of 197 screening mammograms performed in 2004-2005 was independently evaluated by 2 radiologists based on the criteria by Canadian Association of Radiologists (CAR). When disagreement occurred for overall judgement or positioning score, the mammograms were reviewed by a third radiologist. Cohen's kappas for interrater agreement were computed. Multivariable robust Poisson regression models were used to study associations of overall quality and positioning with body mass index (BMI) and breast density.

Results: The CAR criteria were not satisfied for 49.7% of the mammograms. Positioning was the quality attribute most often deficient, with 37.2% of mammograms failing positioning. Interrater agreement ranged from slight (kappa = 0.02 for compression and sharpness) to fair (kappa = 0.30 for exposure). For overall quality, women with a BMI ≥ 30 kg/m(2) had a failure proportion of 67.5% compared with 34.9% for women with a BMI<25 kg/m(2) (risk ratio 2.1 [95% confidence interval, 1.5-3.0]). For positioning, women with a BMI ≥ 30 kg/m(2) had a failure proportion of 53.8% compared with 27.9% for women with a BMI < 25 kg/m(2) (risk ratio 1.9 [95% confidence interval, 1.2-3.1]). Effects of breast density on image quality differed among radiologists.

Conclusion: Despite measures to ensure high-quality imaging, including CAR accreditation, approximately half of this random sample of screening mammograms failed the CAR quality standards. It would be important to define quality targets for screening mammograms carried out in daily practice to interpret such observations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carj.2014.02.001DOI Listing

Publication Analysis

Top Keywords

clinical image
8
image quality
8
daily practice
8
breast cancer
8
screening mammograms
8
mammograms performed
8
interrater agreement
8
women bmi
8
quality
6
mammograms
5

Similar Publications

With the rapid development of nanotechnology, nanoultrasonography has emerged as a promising medical imaging technique that demonstrates significant potential in the diagnosis and treatment of gastrointestinal (GI) diseases. This review discusses the applications of nanoultrasonography in the gastrointestinal field, including improvements in imaging resolution, diagnostic accuracy, latest research findings, and prospects for clinical application. By analyzing existing literature, we explore the role of nanoultrasonography in enhancing imaging resolution, enabling targeted drug delivery, and improving therapeutic outcomes, thereby providing a reference for future research directions.

View Article and Find Full Text PDF

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF

Background: Dental impressions are crucial in pediatric dentistry, but exaggerated gagging can obstruct this process. Various methods have been proposed to manage the gag reflex (GR).

Aim: This study aimed to evaluate and compare the effectiveness of laser acupuncture and electroacupuncture in controlling children's GR.

View Article and Find Full Text PDF

Time perception in bipolar disorder: a systematic review.

Acta Neuropsychiatr

January 2025

IRCCS Ospedale Policlinico San Martino, Genoa, Italy.

Objective: Time distortions characterise severe mental disorders, exhibiting different clinical and neurobiological manifestations. This systematic review aims to explore the existing literature encompassing experimental studies on time perception in patients with bipolar disorder (BD), considering psychopathological and cognitive correlates.

Methods: Studies using an experimental paradigm to objectively measure the capacity to judge time have been searched for.

View Article and Find Full Text PDF

Aims: A simplified version of the history, electrocardiogram, age, risk factors, troponin (HEART) score, excluding troponin, has been proposed to rule-out major adverse cardiac events (MACEs). Computerized history taking (CHT) provides a systematic and automated method to obtain information necessary to calculate the HEAR score. We aimed to evaluate the efficacy and diagnostic accuracy of CHT in calculating the HEAR score for predicting MACE.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!