Effect of Scanning Beam for Superficial Dose in Proton Therapy.

Technol Cancer Res Treat

Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN, USA IU Health Proton Therapy Center, Bloomington, IN, USA 535 Barnhill Dr., RT-041, Indianapolis, IN 46202, USA.

Published: October 2015

Proton beam delivery technology is under development to minimize the scanning spot size for uniform dose to target, but it is also known that the superficial dose could be as high as the dose at Bragg peak for narrow and small proton beams. The objective of this study is to explore the characteristics of dose distribution at shallow depths using Monte Carlo simulation with the FLUKA code for uniform scanning (US) and discrete spot scanning (DSS) proton beams. The results show that the superficial dose for DSS is relatively high compared to US. Additionally, DSS delivers a highly heterogeneous dose to the irradiated surface for comparable doses at Bragg peak. Our simulation shows that the superficial dose can become as high as the Bragg peak when the diameter of the proton beam is reduced. This may compromise the advantage of proton beam therapy for sparing normal tissue, making skin dose a limiting factor for the clinical use of DSS. Finally, the clinical advantage of DSS may not be essential for treating uniform dose across a large target, as in craniospinal irradiation (CSI).

Download full-text PDF

Source
http://dx.doi.org/10.7785/tcrt.2012.500435DOI Listing

Publication Analysis

Top Keywords

superficial dose
16
proton beam
12
bragg peak
12
dose
10
uniform dose
8
dose high
8
proton beams
8
proton
6
dss
5
scanning
4

Similar Publications

Atmospheric Corrosion of Different Steel Types in Urban and Marine Exposure.

Materials (Basel)

December 2024

Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Via Mancinelli 7, 20131 Milan, Italy.

The aim of the present work is to study the atmospheric corrosion behavior of metals exposed to both urban (Milan, IT-Lombardia) and marine (Bonassola, IT-Liguria) atmospheres in Italy. A number of coupons (100 × 150 mm) of carbon steel (CS), hot-dip galvanized steel (GS) and different grades of stainless steel (SS) were exposed. At fixed periods of time, samples were characterized by means of Linear Polarization Resistance (LPR), mass loss tests and corrosion product analysis.

View Article and Find Full Text PDF

Background: The role of local infiltration anesthesia (LIA) in knee surgery is significant. LIA can be more potent than a nerve block, but without the downsides. A wide range of agents are used for LIA, including some off-label medications such as dexmedetomidine and ropivacaine.

View Article and Find Full Text PDF

Introduction: Higher perioperative opioid use has been associated with an increase in periprosthetic joint infection, thromboembolic complications, respiratory events, gastrointestinal complications, cost, and length of stay following hip and knee arthroplasty. Limited data exists regarding the relationship between the postoperative opioid dose and complication rates following primary total shoulder arthroplasty (TSA). The purpose of this study is to investigate the relationship between perioperative opioid consumption and postoperative complications following TSA.

View Article and Find Full Text PDF

NH600001 is a new general anaesthetic drug with a structure similar to etomidate. The objective of this study was to investigate the relationship between concentrations of NH600001 and sedation efficacy based on data from phase I-II studies and factors influencing the pharmacokinetics and pharmacodynamics of NH600001. The dataset consisted of 2 phase I studies in healthy subjects and 1 phase II study in patients undergoing gastroscopy.

View Article and Find Full Text PDF

An investigation of high-Z material for bolus in electron beam therapy.

Biomed Phys Eng Express

December 2024

Department of Radiation Oncology, Northwest Memorial Hospital, Northwestern University Feinberg School of Medicine, Chicago, IL, 60611, United States of America.

. Electron beam treatment often requires bolus to augment surface dose to nearly 100%. There are no optimum bolus materials and hence a high-Z based clothlike material is investigated to reduce air column in treatment that provides optimum surface dose.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!