Radiation fluence changes caused by the dosimeter itself and poor spatial resolution may lead to lack of 3-dimensional (3D) information depending on the features of the dosimeter and quality assurance of dose distributions for high-dose rate (HDR) iridium-192 ((192)Ir) brachytherapy sources is challenging and experimental dosimetry methods used for brachytherapy sources are limited. In this study, we investigated 3D dose distributions of (192)Ir brachytherapy sources for irradiation with single and multiple dwell positions using a normoxic gel dosimeter and compared them with treatment planning system (TPS) calculations. For dose calibration purposes, 100-mL gel-containing vials were irradiated at predefined doses and then scanned in an magnetic resonance (MR) imaging unit. Gel phantoms prepared in 2 spherical glasses were irradiated with (192)Ir for the calculated dwell positions, and MR scans of the phantoms were obtained. The images were analyzed with MATLAB software. Dose distributions and profiles derived with 1-mm resolution were compared with TPS calculations. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. The x-, y-, and z-axes were defined as the sagittal, coronal, and axial planes, respectively, the sagittal and axial planes were defined parallel to the long axis of the source while the coronal plane was defined horizontally to the long axis of the source. The differences between measured and calculated profile widths of 3-cm source length and point source for 70%, 50%, and 30% isodose lines were evaluated at 3 dose levels using 18 profiles of comparison. The calculations for 3-cm source length revealed a difference of > 3mm in 1 coordinate at 50% profile width on the sagittal plane and 3 coordinates at 70% profile width and 2 coordinates at 50% and 30% profile widths on the axial plane. Calculations on the coronal plane for 3-cm source length showed > 3-mm difference in 1 coordinate at 50% and 70% and 2 coordinates at 30% profile widths. The point source measurements and calculations for 50% profile widths revealed a difference > 3mm in 1 coordinate on the sagittal plane and 2 coordinates on the axial plane. The doses of 3 coordinates on the sagittal plane and 4 coordinates on the axial plane could not be evaluated in 30% profile width because of low doses. There was good agreement between the gel dosimetry and TPS results. Gel dosimetry provides dose distributions in all 3 planes at the same time, which enables us to define the dose distributions in any plane with high resolution. It can be used to obtain 3D dose distributions for HDR (192)Ir brachytherapy sources and 3D dose verification of TPS.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2014.04.003DOI Listing

Publication Analysis

Top Keywords

dose distributions
28
brachytherapy sources
20
192ir brachytherapy
16
profile widths
16
gel dosimetry
12
3-cm source
12
source length
12
profile width
12
sagittal plane
12
plane coordinates
12

Similar Publications

Background: Glia mediated neuroinflammation and degeneration of inhibitory GABAergic interneurons are some of the hall marks of pyrethroid neurotoxicity. Here we investigated the sex specific responses of inflammatory cytokines, microglia, astrocyte and parvalbumin positive inhibitory GABAergic interneurons to λ-cyhalothrin (LCT) exposures in rats.

Methods: Equal numbers of male and female rats were given oral corn oil, 2 mg/kg.

View Article and Find Full Text PDF

The impact of glidant addition on the loss-in-weight feeding of active pharmaceutical ingredients.

Int J Pharm

January 2025

Laboratory of Pharmaceutical Technology, Department of Pharmaceutics, Ghent University, Ottergemsesteenweg 460, B-9000 Ghent, Belgium. Electronic address:

In recent years, continuous manufacturing (CM) has become increasingly popular in the pharmaceutical industry for the production of oral solid dosage (OSD) forms. Most of the newly developed active pharmaceutical ingredients (APIs) nowadays are extremely cohesive and sticky with a mean particle size particle of <100μm, a wide particle size distribution (PSD) and a high tendency to agglomerate, making them difficult to accurately dose using loss-in-weight equipment during CM. In this research paper, the effect of various glidants on the volumetric and gravimetric feeding of several APIs was assessed.

View Article and Find Full Text PDF

Assessing and alleviating pain in animals involved in research is critically important. However, the effective implementation of pain management depends on the knowledge and attitudes of the personnel involved. Following a Federation of European Laboratory Animal Science Associations 'Pain in Mice' working group initiative, a questionnaire to survey current practices concerning analgesic use in laboratory mice was distributed to several professional groups in the field of laboratory animal science.

View Article and Find Full Text PDF

Objective: Antithrombotic therapy improves endovascular intervention outcomes for peripheral artery disease. However, there are limited data guiding the choice and duration of these adjuvant therapies. Thus, we explored current antithrombotic prescribing preferences among vascular interventionalists, hypothesizing that there are varied and inconsistent treatment practices among providers.

View Article and Find Full Text PDF

Objective: This study aims to explore the role of estrogen in providing cardioprotective benefits to premenopausal women, examining how hormonal differences between sexes influence the prevalence of cardiovascular diseases (CVDs) in women.

Materials And Methods: Eighteen female Wistar rats were equally distributed into three treatment groups. Animals in Group I (sham-operated) and Group II (ovariectomized [OVX]) received oral saline solution at a dose of 2 mL/kg.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!