A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Optimizing electrical impedance myography measurements by using a multifrequency ratio: a study in Duchenne muscular dystrophy. | LitMetric

Optimizing electrical impedance myography measurements by using a multifrequency ratio: a study in Duchenne muscular dystrophy.

Clin Neurophysiol

Department of Neurology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, United States. Electronic address:

Published: January 2015

Objective: Electrical impedance myography (EIM) is an electrophysiological technique for neuromuscular evaluation that is impacted by subcutaneous fat (SF). Exploiting the differing frequency dependences of muscle and fat, we assessed a 2-frequency EIM phase ratio in Duchenne muscular dystrophy (DMD) boys.

Methods: Twenty-eight DMD boys aged 2-13years underwent EIM and the 6-minute walk test (6MWT). For each subject, 50kHz phase data was input into the numerator while 20-500kHz phase values were input into the denominator. We then performed correlation analyses seeking to identify the denominator frequency that simultaneously optimized SF and 6MWT correlations. This optimized ratio was then tested in 24 healthy boys.

Results: 50kHz phase correlated to 6MWT in DMD boys with R=0.52, p=0.0066, and to SF thickness with R=-0.67, p<0.001. An optimized ratio of 50/200kHz phase reduced the correlation of SF thickness to R=-0.075, p=0.45 while improving the relationship to the 6MWT (R=0.60, p=0.001). In normal subjects, the optimization decreased SF correlation from R=0.61 from R=0.16 with 6MWT correlation remaining unchanged.

Conclusions: The 50/200kHz EIM phase ratio removes the impact of SF while maintaining EIM's association with function.

Significance: The use of a phase ratio may enhance EIM's application for evaluation of neuromuscular disease.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4234696PMC
http://dx.doi.org/10.1016/j.clinph.2014.05.007DOI Listing

Publication Analysis

Top Keywords

electrical impedance
8
impedance myography
8
duchenne muscular
8
muscular dystrophy
8
dmd boys
8
50khz phase
8
optimizing electrical
4
myography measurements
4
measurements multifrequency
4
multifrequency ratio
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!