Spectral fluences of neutrons generated in the heads of the radiotherapeutic linacs Varian Clinac 2100 C/D and Siemens ARTISTE were measured by means of the Bonner spheres spectrometer whose active detector of thermal neutrons was replaced by an activation detector, i.e. a tablet made of pure manganese. Measurements with different collimator settings reveal an interesting dependence of neutron fluence on the area defined by the collimator jaws. The determined neutron spectral fluences were used to derive ambient dose equivalent rate along the treatment coach. To clarify at which components of the linac neutrons are mainly created, the measurements were complemented with MCNPX calculations based on a realistic model of the Varian Clinac.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncu192DOI Listing

Publication Analysis

Top Keywords

neutrons generated
8
radiotherapeutic linacs
8
spectral fluences
8
varian clinac
8
spectral fluence
4
neutrons
4
fluence neutrons
4
generated radiotherapeutic
4
linacs spectral
4
fluences neutrons
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!