Purpose: To evaluate the effect of different methods to convert magnetic resonance (MR) signal intensity (SI) to gadolinium concentration ([Gd]) on estimation and reproducibility of model-free and modeled hepatic perfusion parameters measured with dynamic contrast-enhanced (DCE)-MRI.

Materials And Methods: In this Institutional Review Board (IRB)-approved prospective study, 23 DCE-MRI examinations of the liver were performed on 17 patients. SI was converted to [Gd] using linearity vs. nonlinearity assumptions (using spoiled gradient recalled echo [SPGR] signal equations). The [Gd] vs. time curves were analyzed using model-free parameters and a dual-input single compartment model. Perfusion parameters obtained with the two conversion methods were compared using paired Wilcoxon test. Test-retest and interobserver reproducibility of perfusion parameters were assessed in six patients.

Results: There were significant differences between the two conversion methods for the following parameters: AUC60 (area under the curve at 60 s, P < 0.001), peak gadolinium concentration (Cpeak, P < 0.001), upslope (P < 0.001), Fp (portal flow, P = 0.04), total hepatic flow (Ft, P = 0.007), and MTT (mean transit time, P < 0.001). Our preliminary results showed acceptable to good reproducibility for all model-free parameters for both methods (mean coefficient of variation [CV] range, 11.87-23.7%), except for upslope (CV = 37%). Among modeled parameters, DV (distribution volume) had CV <22% with both methods, PV and MTT showed CV <21% and <29% using SPGR equations, respectively. Other modeled parameters had CV >30% with both methods.

Conclusion: Linearity assumption is acceptable for quantification of model-free hepatic perfusion parameters while the use of SPGR equations and T1 mapping may be recommended for the quantification of modeled hepatic perfusion parameters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4058642PMC
http://dx.doi.org/10.1002/jmri.24341DOI Listing

Publication Analysis

Top Keywords

perfusion parameters
12
hepatic perfusion
8
conversion methods
8
parameters
5
dce-mri liver
4
liver linear
4
linear nonlinear
4
nonlinear conversions
4
conversions hepatic
4
perfusion
4

Similar Publications

Novel Vascular Territory Mapping Algorithm as a Predictive Tool for Identification of Antegrade Flow in Middle Cerebral Artery Occlusion.

Stroke

January 2025

South Western Sydney Clinical School University of New South Wales, Department of Neurology Liverpool Hospital, Ingham Institute of Applied Medical Research, Australia (C.C., L.L., M.P.).

Background: Vascular territory mapping (VTM) software estimates which intracerebral vessel provides predominant arterial flow to a brain voxel. The presence of antegrade flow in the setting of acute middle cerebral artery (MCA) occlusion is associated with improved outcomes. We identify whether VTM software is a determinant of antegrade flow in patients with proximal MCA occlusion.

View Article and Find Full Text PDF

A 3D millifluidic model of a dermal perivascular microenvironment on a chip.

Lab Chip

January 2025

Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Piazza L. da Vinci, 32, 20133 Milan, Italy.

The process of angiogenesis plays a pivotal role in skin regeneration, ensuring the provision of nutrients and oxygen to the nascent tissue, thanks to the formation of novel microvascular networks supporting functional tissue regeneration. Unfortunately, most of the current therapeutic approaches for skin regeneration lack vascularization, required to promote effective angiogenesis. Thus, tridimensional models, complemented with specific biochemical signals, can be a valuable tool to unravel the neovascularization mechanisms and develop novel clinical strategies.

View Article and Find Full Text PDF

Background: Intracranial Atherosclerotic Stenosis (ICAS) is a prevalent etiology of acute ischemic stroke (AIS), leading to significant morbidity and mortality. The accurate diagnosis and treatment of ICAS-induced AIS are critical to improving outcomes. This study assesses the application of Computed Tomography Perfusion (CTP) in predicting ICAS in AIS patients and its potential impact on patient management.

View Article and Find Full Text PDF

The cardioprotective effects of HTK solution and conventional blood cardioplegia in patients with atrial fibrillation undergoing valvular replacement and Cox maze III procedure.

J Cardiothorac Surg

January 2025

Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Women and Children's Healthcare Hospital, No. 123, Tianfei Lane, Mochou Road, Nanjing, Jiangsu, 210004, China.

Introduction: The study was to assess the myocardial protection effects of the histidine-tryptophan-ketoglutarate (HTK) solution and the 4:1 blood cardioplegia (BC) in patients with atrial fibrillation (AF) who were subjected to valvular replacement concomitant with the Cox maze III surgery.

Methods: A cohort of 148 individuals afflicted with AF, who received valve replacement surgery in conjunction with the Cox maze III procedure at our clinic within the period extending from 2015 to 2023, were enrolled. Subsequent to adjustment by propensity score matching (PSM), the patients were categorized into two distinct groups: the HTK group and the BC group.

View Article and Find Full Text PDF

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!