Computer-aided detection (CAD) of breast masses in mammography: combined detection and ensemble classification.

Phys Med Biol

Department of Electrical Engineering, Image and Video Systems Lab, Korea Advanced Institute of Science and Technology (KAIST), 291, Daehak-ro (373-1 Guseong-dong), Yuseong-gu, Daejeon 305-701, Korea.

Published: July 2014

We propose a novel computer-aided detection (CAD) framework of breast masses in mammography. To increase detection sensitivity for various types of mammographic masses, we propose the combined use of different detection algorithms. In particular, we develop a region-of-interest combination mechanism that integrates detection information gained from unsupervised and supervised detection algorithms. Also, to significantly reduce the number of false-positive (FP) detections, the new ensemble classification algorithm is developed. Extensive experiments have been conducted on a benchmark mammogram database. Results show that our combined detection approach can considerably improve the detection sensitivity with a small loss of FP rate, compared to representative detection algorithms previously developed for mammographic CAD systems. The proposed ensemble classification solution also has a dramatic impact on the reduction of FP detections; as much as 70% (from 15 to 4.5 per image) at only cost of 4.6% sensitivity loss (from 90.0% to 85.4%). Moreover, our proposed CAD method performs as well or better (70.7% and 80.0% per 1.5 and 3.5 FPs per image respectively) than the results of mammography CAD algorithms previously reported in the literature.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/59/14/3697DOI Listing

Publication Analysis

Top Keywords

combined detection
12
ensemble classification
12
detection algorithms
12
detection
9
computer-aided detection
8
detection cad
8
breast masses
8
masses mammography
8
detection sensitivity
8
cad
5

Similar Publications

Unraveling the genetic mysteries of spinal muscular atrophy in Chinese families.

Orphanet J Rare Dis

January 2025

The Genetics and Prenatal Diagnosis Center, The Department of Obstetrics and Gynecology, The First Affiliated Hospital of Zhengzhou University, Jianshe Rd, Erqi District, Zhengzhou, 450052, Henan, China.

Objective: Spinal muscular atrophy (SMA) is a motor neuron disorder encompassing 5q and non-5q forms, causing muscle weakness and atrophy due to spinal cord cell degeneration. Understanding its genetic basis is crucial for genetic counseling and personalized treatment options.

Methods: This study retrospectively analyzed families of patients suspected of SMA at our institution from February 2006 to March 2024.

View Article and Find Full Text PDF

Background: To assess the value of combined Monocyte Distribution Width (MDW) and Procalcitonin (PCT) detection in diagnosing and predicting neonatal sepsis outcomes.

Methods: This retrospective study, conducted from January 2022 to December 2023.A retrospective analysis of 39 neonatal sepsis and 30 non-infectious systemic inflammatory response syndrome (SIRS) cases was conducted.

View Article and Find Full Text PDF

Catheter replacement combined with antiplatelet therapy in hemodialysis catheter-related right atrial thrombus: a potential treatment approach.

BMC Cardiovasc Disord

January 2025

General Practice Ward/International Medical Center Ward, General Practice Medical Center, West China Hospital, Sichuan University/West China School of Nursing, Sichuan University, Chengdu, 610041, China.

Background: Catheter-related right atrial thrombus (CRAT) is a severe complication in hemodialysis patients that can lead to catheter dysfunction and pulmonary embolism (PE). However, no standardized treatment strategy currently exists for hemodialysis-related CRAT. This study aims to investigate the efficacy of catheter replacement and antiplatelet therapy in managing hemodialysis CRAT.

View Article and Find Full Text PDF

Prenatal sonographic diagnosis of congenital heart disease (CHD) can lead to improved morbidity and mortality. However, the diagnostic accuracy of ultrasound, the sole prenatal screening tool, remains limited. Failed prenatal or early newborn detection of cyanotic CHD (CCHD) can have disastrous consequences.

View Article and Find Full Text PDF

Accuracy of pulse wave velocity for screening coronary artery disease: a systematic review and meta-analysis.

Diagnosis (Berl)

January 2025

CarVasCare Research Group, Facultad de Enfermería de Cuenca, 16733 Universidad de Castilla-La Mancha , Cuenca, Spain.

Coronary artery disease (CAD) is the leading cause of cardiovascular events and showed high prevalence and healthcare costs in 2019. However, CAD screening for cardiovascular event prevention is invasive and expensive. This study aims to estimate the ability of a noninvasive method, pulse wave velocity (PWV), to detect the presence or absence of coronary artery disease in patients with suspected CAD.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!