A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Assessment of ambiguous base calls in HIV-1 pol population sequences as a biomarker for identification of recent infections in HIV-1 incidence studies. | LitMetric

An increase in the proportion of ambiguous base calls in HIV-1 pol population sequences during the course of infection has been demonstrated in different study populations, and sequence ambiguity thresholds to classify infections as recent or nonrecent have been suggested. The aim of our study was to evaluate sequence ambiguities as a candidate biomarker for use in an HIV-1 incidence assay using samples from antiretroviral treatment-naive seroconverters with known durations of infection (German HIV-1 Seroconverter Study). We used 2,203 HIV-1 pol population sequences derived from 1,334 seroconverters to assess the sequence ambiguity method (SAM). We then compared the serological incidence BED capture enzyme immunoassay (BED-CEIA) with the SAM for a subset of 723 samples from 495 seroconverters and evaluated a multianalyte algorithm that includes BED-CEIA results, SAM results, viral loads, and CD4 cell counts for 453 samples from 325 seroconverters. We observed a significant increase in the proportion of sequence ambiguities with the duration of infection. A sequence ambiguity threshold of 0.5% best identified recent infections with 76.7% accuracy. The mean duration of recency was determined to be 208 (95% confidence interval, 196 to 221) days. In the subset analysis, BED-CEIA achieved a significantly higher accuracy than the SAM (84.6 versus 75.5%, P < 0.001) and results were concordant for 64.2% (464/723) of the samples. Also, the multianalyte algorithm did not show better accuracy than the BED-CEIA (83.4 versus 84.3%, P = 0.786). In conclusion, the SAM and the multianalyte algorithm including SAM were inferior to the BED-CEIA, and the proportion of sequence ambiguities is therefore not a preferable biomarker for HIV-1 incidence testing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4136167PMC
http://dx.doi.org/10.1128/JCM.03289-13DOI Listing

Publication Analysis

Top Keywords

hiv-1 pol
12
pol population
12
population sequences
12
hiv-1 incidence
12
sequence ambiguity
12
sequence ambiguities
12
multianalyte algorithm
12
ambiguous base
8
base calls
8
calls hiv-1
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!