Purpose: Assessment of hip internal rotation (IR) is a critical element in the evaluation of a painful hip, yet there currently exists no consistent method of determining this measurement. The purpose of this study is to report the intra-rater and inter-rater reliability of active and passive hip IR measurement using a digital inclinometer.

Methods: Twenty-five subjects (8 men, 17 women) with asymptomatic hip joints, and no known pathology between the ages of 22 and 42 participated. Two examiners measured hip IR for each subject using a digital inclinometer while visually monitoring pelvic motion. Measurements included passive IR, active IR, and active IR while internally rotating both legs simultaneously. Statistical analysis was performed including intra-rater and inter-rater reliability.

Results: There was no significant difference in measured IR values. Mean range of motion values for all techniques and both examiners ranged from 30.7° to 32.8°. Intra-rater reliability for examiner 1 ranged from 0.84 to 0.92. Inter-rater reliability ranged from 0.89 to 0.93. Of the methods utilized, active IR of a single leg was the most responsive technique with a minimal detectable change value of 5.4°.

Conclusions: Clinical assessment of hip IR range of motion can be performed efficiently and reliably with a digital inclinometer along with visual monitoring of the pelvis for unwanted motion. Findings from this study support unilateral active hip IR in a seated position as a reliable and responsive technique for obtaining hip IR measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00167-014-3096-0DOI Listing

Publication Analysis

Top Keywords

range motion
12
digital inclinometer
12
hip internal
8
internal rotation
8
measurement digital
8
hip
8
assessment hip
8
intra-rater inter-rater
8
inter-rater reliability
8
responsive technique
8

Similar Publications

Recurrent Diffuse Tenosynovial Giant Cell Tumor of the Temporomandibular Joint.

Head Neck Pathol

January 2025

Department of Pathology and Laboratory Medicine, School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.

Purpose: Recurrent diffuse-type tenosynovial giant cell tumor: Clinical presentation, Diagnosis, and Management.

Background: Tenosynovial giant cell tumor (TGCT), is a neoplasm arising from synovial joints, bursae, or tendon sheaths. The initial clinical symptoms are vague and non-diagnostic.

View Article and Find Full Text PDF

Many theories on cognitive effort start from the assumption that cognitive effort can be expended at will, and flexibly up- or down-regulated depending on expected task demand and rewards. However, while effort regulation has been investigated across a wide range of incentive conditions, few investigated the cost of effort regulation itself. Across four experiments, we studied the effects of reward expectancy and task difficulty on effort expenditure in a perceptual decision-making task (random-dot-motion) and a cognitive control task (colour-naming Stroop), and within each task comparted cues between short (cueing the next trial) and long (cueing the next six trials) prediction horizons.

View Article and Find Full Text PDF

Despite frequent occurrences, especially throughout the Appalachian region, fish bite injuries remain largely underreported. Muskellunge anglers are at a particularly heightened risk due to the fish's large mouth and notably sharp teeth. We present a case of a male who sustained an injury to the right volar thumb following a muskellunge bite.

View Article and Find Full Text PDF

Background: The goal of this study was to examine the effects of spinal cord stimulation (SCS) on muscle activity during walking after lower-limb amputation. Amputation results in a loss of sensory feedback and alterations in gait biomechanics, including co-contractions of antagonist muscles about the knee and ankle, and reduced pelvic obliquity range-of-motion and pelvic drop. SCS can restore sensation in the missing limb, but its effects on muscle activation and gait biomechanics have not been studied in people with lower-limb amputation.

View Article and Find Full Text PDF

Comparing the Therapeutic Impact of Strain-Counterstrain and Exercise on Low Back Myofascial Pain Syndrome: A Randomized Trial.

J Multidiscip Healthc

January 2025

Program of Physical Therapy, Department of Medical Rehabilitation Sciences, College of Applied Medical Sciences, King Khalid University, Abha, 61421, Saudi Arabia.

Background: Background: Strain-Counterstrain (SCS) therapy is a manual therapeutic technique used to treat myofascial pain by addressing tender points through passive positioning. Despite anecdotal evidence, limited peer-reviewed research supports its efficacy in chronic low back pain (LBP). This study evaluates the effects of SCS combined with exercise on pain severity, lumbar range of motion (ROM), and functional disability in patients with chronic LBP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!