Determining the optimal method for zygoma fracture reduction is a common challenge. Numerous methods for treating zygomatic arch fractures have been suggested. However, a substantial gap exists between suggested treatment strategies and real-world practice. A general consensus of classification and treatment guidelines for zygomatic arch reduction has not yet been established. We reviewed our cases and propose a new classification of zygomatic arch fracture and a treatment algorithm for successful reduction based on the injury vectors.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/SCS.0000000000000864 | DOI Listing |
Objective: Evaluate the feasibility of the midface degloving approach (MDA) in total maxillectomy without orbital exenteration (TMWOE) and reconstruction for sino-nasal neoplasms.
Study Design: Retrospective case series.
Setting: Tertiary referral center.
J Stomatol Oral Maxillofac Surg
January 2025
Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology, PR China; National Engineering Laboratory for Digital and Material Technology of Stomatology, PR China; Beijing Key Laboratory of Digital Stomatology, PR China; National Clinical Research Center for Oral Diseases, Beijing, PR China. Electronic address:
Objective: To establish an automatic reduction method for unilateral zygomatic fractures based on Iterative Closes Point (ICP) algorithm.
Material And Methods: 60 patients with unilateral type B zygomatic fractures were included. After acquiring CT images, zygomatic fragments were segmented using self-developed software MICSys.
J Craniomaxillofac Surg
December 2024
Department of Craniomaxillofacial Surgery, University Hospital Schleswig-Holstein Campus Kiel, 24105, Kiel, Germany. Electronic address:
The state-of-the-art approach to open reduction and fixation (ORIF) of zygoma fracture fragments is based on manual skills. Achieving high accuracy can be challenging. Our feasibility study on deceased body donors with artificial zygomatic fractures investigated whether virtual repositioning of the fractures and the use of customised 3D-printed titanium osteosynthesis plates was similar in accuracy to the conventional manual procedure, and whether the method was applicable in a clinical setting.
View Article and Find Full Text PDFJ Craniofac Surg
October 2024
Department of Maxillofacial Surgery, Plastic Surgery Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing.
Objective: Pre-bent titanium plates are widely used for internal fixation in L-shaped zygomatic reduction. The aim is to evaluate the effect of pre-bent Z-shaped titanium plate on the narrowing of the zygomatic arch in L-shaped reduction malarplasty.
Methods: Thirty cosmetic female patients were selected and scanned using computed tomography (CT).
J Craniomaxillofac Surg
December 2024
School of Medicine and Health Sciences, University of Barcelona, Barcelona, Spain; IDIBELL Institute, Barcelona, Spain.
Real-time surgical navigation systems (dynamic computer-aided surgery, d-CAIS) and static guided surgery (static computer-aided surgery, s-CAIS) have been shown to enhance the accuracy of zygomatic implant (ZI) placement. The objective of this systematic review was to evaluate and compare the accuracy and risk of complications associated with d-CAIS and s-CAIS in ZI placement. A systematic review of published studies involving more than 4 patients was conducted to assess and compare the accuracy of d-CAIS and s-CAIS in zygomatic implant placement.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!