Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The objectives of this pilot study were to develop a video fluoroscopy kinematics method for the assessment of the coxofemoral joint in cats with and without osteoarthritis (OA)-associated disability. Two non-OA cats and four cats affected by coxofemoral OA were evaluated by video fluoroscopy. Video fluoroscopic images of the coxofemoral joints were captured at 120 frames/s using a customized C-arm X-ray system while cats walked freely on a treadmill at 0.4 m/s. The angle patterns over time of the coxofemoral joints were extracted using a graphic user interface following four steps: (i) correction for image distortion; (ii) image denoising and contrast enhancement; (iii) frame-to-frame anatomical marker identification; and (iv) statistical gait analysis. Reliability analysis was performed. The cats with OA presented greater intra-subject stride and gait cycle variability. Three cats with OA presented a left-right asymmetry in the range of movement of the coxofemoral joint angle in the sagittal plane (two with no overlap of the 95% confidence interval, and one with only a slight overlap) consistent with their painful OA joint, and a longer gait cycle duration. Reliability analysis revealed an absolute variation in the coxofemoral joint angle of 2º-6º, indicating that the two-dimensional video fluoroscopy technique provided reliable data. Improvement of this method is recommended: variability would likely be reduced if a larger field of view could be recorded, allowing the identification and tracking of each femoral axis, rather than the trochanter landmarks. The range of movement of the coxofemoral joint has the potential to be an objective marker of OA-associated disability.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10816421 | PMC |
http://dx.doi.org/10.1177/1098612X14537261 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!