A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Continuous high-pressure negative suction drain: new powerful tool for closed wound management: clinical experience. | LitMetric

Background: Although various reconstructive flap surgeries have been successfully performed, there still are difficult wound complications, such as seroma formation, wound margin necrosis, delayed wound healing, and even flap failures. The negative-pressure wound therapy has been described in detail in the literature to assist open chronic/complex wound closure in reconstructive surgery. However, the negative-pressure wound therapy was difficult to be applied under the incisional closed wounds.

Methods: A total of 23 patients underwent the various reconstructive flap surgeries with continuous high-pressure negative suction drain. Instead of using regular suction units, Barovac (50-90 mm Hg, Sewoon Medical, Seoul, Republic of Korea) drainage tubes were connected to the wall suction unit, providing continuous high-powered negative pressure. In addition, continuous subatmospheric suction pressure (100-300 mm Hg) was applied. Outcome of the measures was obtained from the incidence of seroma, volume of postoperative drainage, hospitalization period, and incidence of other typical wound complications. Dead space was evaluated postoperatively with ultrasonography.

Results: Using continuous high-pressure negative suction drain, successful management of seroma was obtained without any major complication such as wound infection, flap loss, and wound margin necrosis, except for only 1 case of seroma after discharge from the hospital. The indwelling time of the drain in the latissimus dorsi donor site was significantly reduced in comparison with the authors' previous data (P = 0.047). The volume of drainage and hospitalization period were also reduced; however, these were not statistically significant. The dead space with continuous high-pressure negative suction drain was more reduced than in the control group in the immediate postoperative period and confirmed with ultrasonography.

Conclusions: Continuous high-pressure negative suction drain might be the simple and powerful solution in the management of challenging closed wounds.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0000000000000575DOI Listing

Publication Analysis

Top Keywords

continuous high-pressure
20
high-pressure negative
20
negative suction
20
suction drain
20
wound
10
suction
8
reconstructive flap
8
flap surgeries
8
wound complications
8
wound margin
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!