Background: Upright examination procedures like radiology, thermography, manual muscle testing, and spinal motion palpation may lead to spinal interventions with the patient prone. The reliability and accuracy of mapping upright examination findings to the prone position is unknown. This study had 2 primary goals: (1) investigate how erroneous spine-scapular landmark associations may lead to errors in treating and charting spine levels; and (2) study the interexaminer reliability of a novel method for mapping upright spinal sites to the prone position.

Methods: Experiment 1 was a thought experiment exploring the consequences of depending on the erroneous landmark association of the inferior scapular tip with the T7 spinous process upright and T6 spinous process prone (relatively recent studies suggest these levels are T8 and T9, respectively). This allowed deduction of targeting and charting errors. In experiment 2, 10 examiners (2 experienced, 8 novice) used an index finger to maintain contact with a mid-thoracic spinous process as each of 2 participants slowly moved from the upright to the prone position. Interexaminer reliability was assessed by computing Intraclass Correlation Coefficient, standard error of the mean, root mean squared error, and the absolute value of the mean difference for each examiner from the 10 examiner mean for each of the 2 participants.

Results: The thought experiment suggesting that using the (inaccurate) scapular tip landmark rule would result in a 3 level targeting and charting error when radiological findings are mapped to the prone position. Physical upright exam procedures like motion palpation would result in a 2 level targeting error for intervention, and a 3 level error for charting. The reliability experiment showed examiners accurately maintained contact with the same thoracic spinous process as the participant went from upright to prone, ICC (2,1) = 0.83.

Conclusions: As manual therapists, the authors have emphasized how targeting errors may impact upon manual care of the spine. Practitioners in other fields that need to accurately locate spinal levels, such as acupuncture and anesthesiology, would also be expected to draw important conclusions from these findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4046139PMC
http://dx.doi.org/10.1186/2045-709X-22-20DOI Listing

Publication Analysis

Top Keywords

prone position
16
spinous process
16
upright prone
12
interexaminer reliability
12
upright
8
prone
8
position interexaminer
8
upright examination
8
motion palpation
8
mapping upright
8

Similar Publications

Transoral resection of a symptomatic odontoid process aneurysmal bone cyst: illustrative case.

J Neurosurg Case Lessons

January 2025

Departments of Neurosurgery, NYU Langone Health, New York, New York.

Background: Aneurysmal bone cysts (ABCs) are slow-growing, expansile bone tumors most often observed in the long bones and lumbar and thoracic spine. Anterior column ABCs of the spine are rare, and few cases have described their surgical management, particularly for lesions with extension into the odontoid process and the bilateral C2 pedicles. In the present case, the authors describe a two-stage strategy for resection of a symptomatic 2.

View Article and Find Full Text PDF

Background: Vascularized bone grafts (VBGs) are currently the main surgical option for the restoration of humeral bone defects particularly when defects are larger than 6 cm. Because it offers a strong, rapid blood supply, VBGs easily integrate into the recipient sites and undergo active resorption and remodeling into healthy bone through primary bone healing. Additionally, they support the recipient site's immune system in preventing and reducing infection.

View Article and Find Full Text PDF

Introduction: Endoscopic spine surgery (ESS) is a minimally invasive technique that allows for direct visualization of spinal pathologies and has become a safe and effective alternative to traditional open spine surgery. Conventionally performed in the prone position, biportal endoscopy can also be done in the lateral position to avoid prone-associated complications. To our knowledge, the use of unilateral biportal endoscopy (UBE) in the lateral position has not been previously reported.

View Article and Find Full Text PDF

Interpretable flash flood susceptibility mapping in Yarlung Tsangpo River Basin using H2O Auto-ML.

Sci Rep

January 2025

Key Laboratory of Water Cycle and Related Land Surface Processes, Institute of Geographic Sciences and Natural Resources Research (IGSNRR), Chinese Academy of Sciences (CAS), Beijing, 100101, China.

Flash flood susceptibility mapping is essential for identifying areas prone to flooding events and aiding decision-makers in formulating effective prevention measures. This study aims to evaluate the flash flood susceptibility in the Yarlung Tsangpo River Basin (YTRB) using multiple machine learning (ML) models facilitated by the H2O automated ML platform. The best-performing model was used to generate a flash flood susceptibility map, and its interpretability was analyzed using the Shapley Additive Explanations (SHAP) tree interpretation method.

View Article and Find Full Text PDF

Normalization of Retinal Birefringence Scanning Signals.

Sensors (Basel)

December 2024

Ophthalmic Instrumentation Development Lab, The Wilmer Eye Institute, The Johns Hopkins University School of Medicine, Wilmer 233, 600 N. Wolfe St., Baltimore, MD 21287, USA.

Signal amplitudes obtained from retinal scanning depend on numerous factors. Working with polarized light to interrogate the retina, large parts of which are birefringent, is even more prone to artifacts. This article demonstrates the necessity of using normalization when working with retinal birefringence scanning signals in polarization-sensitive ophthalmic instruments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!