Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To determine the interexaminer and intraexaminer repeatability of the modified Thorington test (TH) for distance vision in young adults and to compare these results with those observed for the heterophoria tests most commonly used in clinical practice. Agreement among tests was also assessed.
Methods: Distance heterophoria was quantified on two separate occasions by two examiners in 110 subjects aged 18 to 32 years (mean, 19.74 years; SD, 2.5 years) using four different tests: cover test (CT) Von Graefe, Maddox rod, and modified TH. The repeatability of the tests and agreement between them was estimated by the Bland and Altman method whereby the mean difference and the 95% limits of agreement were determined as the coefficient of repeatability (COR) and coefficient of agreement.
Results: The Thorington test showed best interexaminer repeatability (COR = ±1.43Δ), followed closely by CT (COR = ±1.65Δ), whereas best intraexaminer repeatability was observed for CT (COR = ±1.28Δ) followed by TH (COR = ±1.51Δ). Among the different combinations of tests, TH and CT showed best agreement indicated by the lowest coefficient of agreement (±2.23Δ) and a low mean difference (-0.63Δ) between measurements.
Conclusions: Good interexaminer and intraexaminer repeatability was observed for both TH and CT, and agreement between the two tests was also good. Given the simple administration of the TH, we recommend its clinical use to quantify distance horizontal heterophoria.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/OPX.0000000000000297 | DOI Listing |