Measurement of atropisomer racemization kinetics using segmented flow technology.

ACS Med Chem Lett

Neuroscience Chemistry, Pfizer Global Research and Development , Groton, Connecticut 06340, United States.

Published: May 2012

When stable atropisomers are encountered by drug discovery teams, they can have important implications due to potential differences in their biological activity, pharmacokinetics, and toxicity. Knowledge of an atropisomer's activation parameters for interconversion is required to facilitate informed decisions on how to proceed. Herein, we communicate the development of a new method for the rapid measurement of atropisomer racemization kinetics utilizing segmented flow technology. This method leverages the speed, accuracy, low sample requirement, safety, and semiautomated nature of flow instrumentation to facilitate the acquisition of kinetics data required for experimentally probing atropisomer activation parameters. Measured kinetics data obtained for the atropo isomerization of AMPA antagonist CP-465021 using segmented flow and traditional thermal methods were compared to validate the method.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4025797PMC
http://dx.doi.org/10.1021/ml2003108DOI Listing

Publication Analysis

Top Keywords

segmented flow
12
measurement atropisomer
8
atropisomer racemization
8
racemization kinetics
8
flow technology
8
activation parameters
8
kinetics data
8
kinetics
4
kinetics segmented
4
flow
4

Similar Publications

To assess the effectiveness of transcatheter aortic valve replacement (TAVR) on electrocardiographic remodeling in patients with severe aortic stenosis (AS), and identify its influencing factors. A cohort study was conducted on patients with a confirmed diagnosis of severe AS who successfully underwent TAVR at the Second Affiliated Hospital of Dalian Medical University between June 2018 and March 2023. Data, including standard 15-lead electrocardiograms and echocardiograms, were collected before the operation, 1 week after the operation, and 3 months after the operation.

View Article and Find Full Text PDF

Impact of coronary flow restoration just before stent deployment in primary percutaneous coronary intervention.

Cardiovasc Interv Ther

January 2025

Division of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama City, 330-8503, Japan.

This study aimed to investigate the relationship between the restoration of coronary flow just before stent deployment and the final thrombolysis in myocardial infarction (TIMI) flow grade 3 in patients with ST-segment elevation myocardial infarction (STEMI) whose initial TIMI flow grade ≤ 1. In primary percutaneous coronary intervention (PCI), initial TMI flow grade ≤ 1 is closely associated with suboptimal final TIMI flow grade. We included 466 STEMI patients with initial TIMI flow grade ≤ 1 and divided into a restored flow group or an unrestored flow group according to the TIMI flow grade just before stent deployment.

View Article and Find Full Text PDF

Enhancing both ionic conductivity and mechanical robustness remains a major challenge in designing solid-state electrolytes for lithium batteries. This work presents a novel approach in designing mechanically robust and highly conductive solid-state electrolytes, which involves ionic liquid-based cross-linked polymer networks incorporating polymeric ionic liquids (PILs). First, linear PILs with different side groups were synthesized for optimizing the structure.

View Article and Find Full Text PDF

The presentation of pulmonary vasculature in pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries (PA/VSD/MAPCA) is highly variable-as is the number, size and position of the MAPCAs and their relationship with the native pulmonary artery system. The priority in the management of this disease should be attaining timely and complete unifocalization, as opposed to single-stage full repair in every case. The merit of early unifocalization is that it secures the pulmonary vascular bed by (a) avoiding loss of lung segments from progressive stenosis/atresia of MAPCA origins, (b) preventing lung injury from high pressure/flow in areas fed by large, unobstructed MAPCAs, and (c) restoring central continuity of the pulmonary vasculature.

View Article and Find Full Text PDF

Advances in the design and application of contactless conductivity detectors for separation, flow-through, microfluidic and sensing techniques: A review.

Anal Chim Acta

February 2025

Department of Hygiene, Third Faculty of Medicine, Charles University, Ruská 87, 100 00, Prague 10, Czech Republic. Electronic address:

The review focuses on the design of detection cells, the use of microcontrollers for processing and evaluation of the detection signal, and the development of multi-detection systems for electromigration, liquid chromatography, flow-through and microfluidic techniques. A separate section is the introduction of modern 3D printing techniques and the use of new printing materials for the design of multidetection systems. In addition to traditional utilisation in separation techniques, new versions of contactless conductivity detectors are finding applications in FIA, SIA, portable and paper based analytical systems or as independent sensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!