Is it Feasible to Use the Commercially Available Autoquantitation Software for the Evaluation of Myocardial Viability on Small-Animal Cardiac F-18 FDG PET Scan?

Nucl Med Mol Imaging

Department of Nuclear Medicine, Korea University Anam Hospital, 126-1, Anam-Dong 5-Ga, Seongbuk-Gu, Seoul, 136-705 South Korea ; Department of Nuclear Medicine, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 110-744 South Korea.

Published: June 2013

Purpose: To evaluate the reliability of quantitation of myocardial viability on cardiac F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) scans with three different methods of visual scoring system, autoquantitation using commercially available autoquantitation software, and infarct-size measurement using histogram-based maximum pixel threshold identification on polar-map in rat hearts.

Methods: A myocardial infarct (MI) model was made by left anterior descending artery (LAD) ligation in rat hearts. Eighteen MI rats underwent cardiac FDG-PET-computed tomography (CT) twice within a 4-week interval. Myocardium was partitioned into 20 segments for the comparison, and then we quantitated non-viable myocardium on cardiac FDG PET-CT with three different methods: method A-infarct-size measurement using histogram-based maximum pixel threshold identification on polar-map; method B-summed MI score (SMS) by a four-point visual scoring system; method C-metabolic non-viable values by commercially available autoquantitation software. Changes of non-viable myocardium on serial PET-CT scans with three different methods were calculated by the change of each parameter. Correlation and reproducibility were evaluated between the different methods.

Results: Infarct-size measurement, visual SMS, and non-viable values by autoquantitation software presented proportional relationship to each other. All the parameters of methods A, B, and C showed relatively good correlation between each other. Among them, infarct-size measurement (method A) and autoquantitation software (method C) showed the best correlation (r = 0.87, p < 0.001). When we evaluated the changes of non-viable myocardium on the serial FDG-PET-CT- however, autoquantitation program showed less correlation with the other methods. Visual assessment (method B) and those of infarct size (method A) showed the best correlation (r = 0.54, p = 0.02) for the assessment of interval changes.

Conclusions: Commercially available quantitation software could be applied to measure the myocardial viability on small animal cardiac FDG-PET-CT scan. This kind of quantitation showed good correlation with infarct size measurement by histogram-based maximum pixel threshold identification. However, this method showed the weak correlation when applied in the measuring the changes of non-viable myocardium on the serial scans, which means that the caution will be needed to evaluate the changes on the serial monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4041970PMC
http://dx.doi.org/10.1007/s13139-013-0206-8DOI Listing

Publication Analysis

Top Keywords

autoquantitation software
20
commercially autoquantitation
12
three methods
12
infarct-size measurement
12
myocardial viability
8
cardiac f-18
8
scans three
8
visual scoring
8
scoring system
8
measurement histogram-based
8

Similar Publications

Is it Feasible to Use the Commercially Available Autoquantitation Software for the Evaluation of Myocardial Viability on Small-Animal Cardiac F-18 FDG PET Scan?

Nucl Med Mol Imaging

June 2013

Department of Nuclear Medicine, Korea University Anam Hospital, 126-1, Anam-Dong 5-Ga, Seongbuk-Gu, Seoul, 136-705 South Korea ; Department of Nuclear Medicine, Seoul National University Hospital, 101 Daehak-Ro, Jongno-Gu, Seoul, 110-744 South Korea.

Purpose: To evaluate the reliability of quantitation of myocardial viability on cardiac F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) scans with three different methods of visual scoring system, autoquantitation using commercially available autoquantitation software, and infarct-size measurement using histogram-based maximum pixel threshold identification on polar-map in rat hearts.

Methods: A myocardial infarct (MI) model was made by left anterior descending artery (LAD) ligation in rat hearts. Eighteen MI rats underwent cardiac FDG-PET-computed tomography (CT) twice within a 4-week interval.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!