A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

HOI versus HOIO selectivity of a molten-type AgI electrode. | LitMetric

Unlabelled: AgI electrode is often applied not only to determine iodine concentration but also to follow oscillations in the weakly acidic medium of the Bray-Liebhafsky and Briggs-Rauscher reactions where it partly follows the hypoiodous acid (HOI) concentration. It is known that HOI attacks its matrix in the corrosion reaction: AgI + HOI + H(+) ⇆ Ag(+) + I2 + H2O and the AgI electrode measures the silver ion concentration produced in that reaction. The signal of the electrode can be the basis of sensitive and selective HOI concentration measurements only supposing that an analogous corrosive reaction between AgI and iodous acid (HOIO) can be neglected. To prove that assumption, the authors calibrated a molten-type AgI electrode for I(-), Ag(+), HOI, and HOIO in 1 M sulfuric acid and measured the electrode potential in the disproportionation of HOIO, which is relatively slow in that medium. Measured and simulated electrode potential versus time diagrams showed good agreement, assuming that the electrode potential is determined by the HOI concentration exclusively and the contribution of HOIO is negligible. An independent and more direct experiment was also performed giving the same result. HOIO was produced with a new improved recipe.

Conclusion: an AgI electrode can be applied to measure the HOI concentration selectively above the so-called solubility limit potential.

Download full-text PDF

Source
http://dx.doi.org/10.1021/jp504052wDOI Listing

Publication Analysis

Top Keywords

agi electrode
20
hoi concentration
16
electrode potential
12
electrode
9
hoi
8
molten-type agi
8
electrode applied
8
reaction agi
8
agi
7
hoio
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!